Technical data

Technology functions
CPU 317T: Technology Functions
A5E00251798-03
6-9
MC_Power - ErrorIDs
ErrorID
Error message Description / to correct or avoid error
0000 No error -
8001 Internal fault Faulty or inconsistent project / software.
8005 Command canceled because of
input buffer overflow
The rate of successive commands output to the
technology by the user program is too high.
8007 An internal error has occurred at the
job interface
Due to an internal problem in the S7 system, commands
can not be accepted.
Check the consistency of your project data, then
download all system data to the module again.
8043 Illegal parameter value
Concerns the input parameters Mode or StopMode.
The Mode or Stopmode parameter contains an invalid
value, e.g. Mode = 129.
8044 Task not supported by the
technology object
Apply MC_Power to a cam, for example.
804C Command output rate too high The command output rate with the same instance DB was
higher than the command interface was able to accept.
The second command is rejected in order not to violate
consistency the first.
For high command output rates, always use a separate
instance DB, or send the command again. Please note,
that although the first accepted command may be busy,
you may not be able to monitor it at the status outputs.
8050 Technology not ready During testing with breakpoints (CPU in HOLD), the
technology function has output a new command to the
technology. The command is rejected.
804E Permitted is only one instance per
axis
The technology function may only be active at one
instance per axis.
Another MC_Power (Busy = TRUE) is already active at
the specified axis.
Use only one instance, or terminate the current command.
804F Change of the axis at MC_Power is
not permitted.
An axis was locked (Enable 1->0) while an axis other than
the one set at the enable parameter was set at input
parameter "Axis.". You can only disable an axis which
was actually enabled by this instance of MC_Power.