Technical data
Configuration
CPU 317T: Technology Functions
A5E00251798-03
4-117
Step Description
9.
The "External encoder configuration - Encoder data" dialog box is
displayed. The contents of the
dialog box depends on the selected encoder type. The figure shows the dialog box for the
SIMODRIVE Sensor encoder.
• ADI4 Settings
Enter the encoder data which you have configured in HW Config at the ADI4.
• Settings for the encoder systems of the drives SIMODRIVE, MASTERDRIVES, etc.
Enter the encoder data which you entered at the drive configuration.
• Settings for SIMODRIVE sensor
Enter the values for the SIMODRIVE sensor as shown below:
Parameter Single-turn
encoder
Multi-turn encoder
Encoder pulses per revolution 8192 8192
Multiplication factor of the absolute actual
value
1 1
Multiplication factor of the cyclic actual value 524288 128
Number of data bits 25 25
Confirm your entry with "Continue".