Technical data

Configuration
CPU 317T: Technology Functions
A5E00251798-03
4-117
Step Description
9.
The "External encoder configuration - Encoder data" dialog box is
displayed. The contents of the
dialog box depends on the selected encoder type. The figure shows the dialog box for the
SIMODRIVE Sensor encoder.
ADI4 Settings
Enter the encoder data which you have configured in HW Config at the ADI4.
Settings for the encoder systems of the drives SIMODRIVE, MASTERDRIVES, etc.
Enter the encoder data which you entered at the drive configuration.
Settings for SIMODRIVE sensor
Enter the values for the SIMODRIVE sensor as shown below:
Parameter Single-turn
encoder
Multi-turn encoder
Encoder pulses per revolution 8192 8192
Multiplication factor of the absolute actual
value
1 1
Multiplication factor of the cyclic actual value 524288 128
Number of data bits 25 25
Confirm your entry with "Continue".