Technical data

Configuration
CPU 317T: Technology Functions
A5E00251798-03
4-83
The synchronization mode is defined in the "Position reference" drop-down list:
Setting Meaning
Synchronize starting at the
synchronization position
Synchronization starts at the synchronization position. The
synchronization length is derived form the time-based synchronization
profile in dynamic data, and for a leading axis-specific synchronization
profile from the "Synchronization length" parameter. The following axis
is synchronized when this length has been passed.
Synchronize before the
synchronization position is
reached
In this synchronization mode, the following axis is in synchronism to
the leading axis when it reaches the synchronization position.
The starting point of synchronization with time-based synchronization
profile is determined by the dynamic data, and with leading axis-
specific synchronization profile by the "Synchronization length"
parameter.
Synchronize symmetrically to
synchronization position
In this mode, synchronism is reached at the middle of the
synchronization length. Synchronized motion starts before the
synchronization position is reached, and ends when this position is
passed.
The axes are synchronized based on the profile, with reference to the
synchronization length or dynamic settings.
Most recent settings Not applicable
Synchronization direction