Technical data

Configuration
CPU 317T: Technology Functions
4-80 A5E00251798-03
Advanced synchronization
In advanced synchronization mode, the synchronization motion starts:
at the start point of synchronization and with optimal time-based
synchronization, based on the preset dynamic response parameters, and at a
constant master setpoint value (dynamic control value.)
Immediately, if an optimal synchronization time can not be calculated, and the
synchronization position can be reached (for example, if the control value is
static.)
Note
If an optimal synchronization is not possible, a reverse motion may be generated.
Any change in the velocity control value is applied to the dynamic values of the
synchronization process. A warning message is output if the configured tolerance
limit is violated.
If the control value sign reverses during synchronization, synchronization is
canceled with error.
Retarded synchronization
In retarded synchronization mode
the synchronization motion starts when the start criterion is satisfied
only a trapezoidal velocity profile is supported
If a velocity profile with constant acceleration is set, a "Dynamic response of
motion profiles ... can not be maintained" alarm is generated, and the system
automatically switches over to a trapezoidal velocity profile.