Technical data

What's new in S7-Technology V2.0
CPU 317T: Technology Functions
A5E00251798-03
1-3
New and enhanced basic functions
MC_Reset
It is now possible to restart based on a specific cam disk. The restart function
restores the cam disk originally configured in S7T Config. During the restart of
a technology object, the system continues to process new commands output to
other technology objects.
MC_ReadSysParameter
The new input parameter Index allows read access to multiple instances of a
parameter.
In combination with the new functionality of MC_WriteParameter, the user can
now save a backup copy of the data of an absolute value encoder adjustment
in preparation for a CPU replacement.
MC_WriteParameter
The new Index input parameter can be used to write to several instances of
parameter sets / data records.
In combination with the new functionality of MC_ReadParameter, the user can
now save a backup copy of the data of an absolute value encoder adjustment
in preparation for a CPU replacement.
MC_ReadPeriphery, MC_WritePeriphery
The new technology functions "MC_ReadPeriphery" and "MC_WritePeriphery"
provide read / write access to the I/O image DP(DRIVE) of the integrated
technology. This functionality allows you to write the I/O image of a standard
slave connected to DP(DRIVE) to the I/O image DP(DRIVE) of the integrated
technology, for example.
MC_ReadDriveParameter, MC_WriteDriveParameter
The new technology functions "MC_ReadDriveParameter" and
"MC_WriteDriveParameter" provide read / write access to the parameters of a
drive connected to DP(DRIVE).
Operating SINAMICS Terminal Modules TM15 and TM17 High Feature in
combination with the SINAMICS S120 system
S7-Technology V2.0 supports the operation of SINAMICS Terminal Modules TM15
and TM17 High Feature in combination with the SINAMICS S120 system. The
Terminal Modules can be used as measuring sensor inputs and (high speed) cam
outputs.
Order numbers are found under "Available components and systems."