Technical data
Configuration
CPU 317T: Technology Functions
A5E00251798-03
4-59
4.5.7.6 Traversing with a non-homed axis
In the Axis > Homing dialog box, you specify whether the absolute positioning
function is available at an axis which is not homed.
Optional settings for "Homing required":
• No: Relative and absolute motions are possible. The software limit switches
are monitored.
• Yes: relative motion only. The software limit switches are not monitored as long
as the axis is not homed.