8.
If a physical drive is selected, the dialog box provides additional options.
Select a relevant "Axis" from the "Drive" field if the selected drive is a multiple axis module
(SIMODRIVE 611 universal double axis module, ADI 4, SINAMICS S120, for example.).
The view boxes "log. HW addresses", "Input" and "Output" show the drive's logical addresses
you set in the drive configuration in HW Config.
During a reconfiguration the message type set in HW Config is entered as the default setting in
the fold-down list box (also refer to Selecting the Message Type). If the telegram set in
HW Config is unknown or was edited by the user, and thus does not match any known standard
telegram, the telegram wizard helps you to make the correct selection from a drop-down list.
Enter the rated velocity of the motor in "Rated rpm" This value is relevant for the velocity rating
and must therefore correspond with the drive configuration.
Click "Continue"
Result: The "Interaction axis - drive" dialog box opens. Confirm the dialog box with "OK." The
S7T Config Online Help opens. Close the Online Help and continue with the axis configuration.
Note
The telegram type you configured in S7T Config for the interface of the technology
object for the drive component must match the telegram type of the component
configured in HW Config.