Technical data
Learning units
3.2 2. Step: Configuring CPU 317T-2 DP with HW Config
Sequence Activity Result
3 Open the "Hardware Catalog" and select the "SIMATIC Technology CPU" hardware profile in the "Profile"
drop-down list.
Result: The "SIMATIC Technology" directory is displayed.
4 Insert a mounting rail using drag-and-drop in the station window of
HW Config.
This creates a mounting rail.
5 Drag-and-drop the "PS 307 5A" power supply module onto the
mounting rail.
The power supply module appears
on the mounting rail.
6 Add the Technology CPU to the mounting rail by means of drag-and-
drop.
A message box appears.
7 You change the transmission rate in the next step.
Confirm the message box with "OK.“
In the next dialog box, you can set
the PROFIBUS properties of the DP
(DRIVE).
8 Confirm the default settings of the PROFIBUS configuration with
"OK".
CPU 317T-2 DP: Controlling a SINAMICS S120
Getting Started, 12/2005, A5E00480391-01
3-3