User manual

Connect Tech Blue Heat/Net User Manual
94 Revision 0.17
Using SCM/TCM
Log onto the Blue Heat/Net. The default login for the TCM is root. (There is no login necessary
if using SCM). The default password for both TCM and the SCM is password.
Enter net net=198.182.196.0. This will set 198.182.196.0 to the server, gateway and the unit’s IP
in one step.
Enter net my_ip=15. This will set the unit’s IP to 198.182.196.15.
Enter net server_ip=1. This will set the server IP to 198.182.196.1.
Enter net gateway_ip=2. This will set the gateway IP to 198.182.196.2.
Enter net subnetmask=255.255.255.0. This will set the subnet mask.
Enter net dns_ip=3. This will set the DNS IP to 198.182.196.3
Enter net dhcp=no. This will turn off DHCP on the unit.
Enter save. This will save the configuration set above to flash memory.
Enter exit. The unit will reboot using the new settings.
Using WCM
Connect to the Blue Heat/Net using a web browser by entering the current IP of the unit in the
address.
Log on by supplying the username and password. The default login is wcm and the default
password is password.
Select the Blue Heat/Net Settings page and fill in the server IP, Blue Heat/Net IP, Gateway IP,
DNS IP and subnet mask as defined above.
Ensure the Use DHCP option is set to no
Click on the Save to Flash button to store the changes.
DHCP Setup
In many modern networks IP numbers are not static but are automatically assigned by a DHCP
server and can change over time or on each power up.
DHCP must be enabled on the Blue Heat/Net because it is shipped to use a default static IP
(192.168.42.1)
Using SCM/TCM
Log onto the Blue Heat/Net. (If using the SCM, no login is required. For the TCM, the default
login is root). The default password for both SCM and TCM is password.
Enter net dhcp=yes. This will turn on DHCP on the unit.
Enter net dns_ip=3. This will set the DNS IP to 198.182.196.3
Enter save. This will save the configuration we just set to flash memory.
Enter exit. The unit will reboot using the new settings.