Syntax: port [port#]
[line_mode= | lmode=]
[baudrate= | baud=]
[data_bits= | bits=]
[parity= | par=]
[stop_bits= | stop=]
[software_flow= | sflow=]
[xoff=]
[xon=]
[hardware_flow= | hflow=]
[local_loopback= | llb=]
[special_char_mode= | scm=]
[error_char= | errch=]
[break_char= | brkch=]
[event_char= | evtch=]
[use_xoff_xon_limits= | xlim=]
[xofflim=]
[xonlim=]
[escape_char= | esc=]
[fifos=]
[txload=]
Description: This command establishes the initial settings of the serial ports when the Blue
Heat/Net is powered up.
Options: port#
This specifies the port number to change or query. If the port number is omitted,
the command returns a summary of all the ports on the Blue Heat/Net.
N where N is 1 to the number of ports on the unit.
line_mode= | lmode=
This is used to change the Line Interface Mode settings on units supporting this
feature.
232 Sets RS-232 mode
full Sets RS-422/485 Full-Duplex mode
4wire Sets RS-422/485 4-Wire Multi-drop mode
2wire Sets RS-422/485 2-wire Multi-drop mode (½ Duplex)
±tri Enables or disables line driver Tri-State at power-up. (Valid
only with RS-422/485 Full Duplex mode).
±bt Enables or disables Line Bias and Termination on RS-485
ports
baudrate= | baud=
This sets the baud rate.
50 to 460800 (default 9600, maximum 230400 baud on RJ-45 models)
data_bits= | bits=
This sets the number of data bits in each character (byte).
5, 6, 7 or 8 (default)
parity= | par=
This sets the parity mode
n no parity (default)
e even
o odd
0 force 0 (space parity)
1 force 1 (mark parity)