User manual

Connect Tech Blue Heat/Net User Manual
Revision 0.17 29
help
Syntax: help
Description: Displays a brief list of all the commands.
Options: There are no options for the help command. Please note that specific help for the
options of each command can be obtained by entering any command with a
single “?” argument. An example would be net ?
info
Syntax: info [-v]
Description: This command is used to show basic information about the Blue Heat/Net unit,
like Serial Number and Version Numbers, and performs a confidence (CRC and
Decompression verification) test of the contents of the Flash memory.
Options: -v
This option disables the confidence tests.
net
Syntax: net [network= | net=]
[my_ip= | mip=]
[server_ip= | sip=]
[gateway_ip= | gip=]
[subnetmask= | snm=]
[broadcast_ip= | bcip=]
[dns_ip=]
[domain=]
[host name=1 host=]
[tcp=]
[mac=]
[dhcp=]
Description: Establishes the network settings.
Options: network= | net=
Sets the “network” portion of the IP address into my_ip, server_ip and
gateway_ip. The address entered is masked by the subnet mask setting before
being applied. This command is a shortcut for quickly setting all the IP
addresses of the unit. See note below.
my_ip= | mip=
This sets the IP address of the Blue Heat/Net unit (default is 192.168.42.1). See
note below.
server_ip= | sip=
This sets the Server IP address. This address determines the address of the
Server to use when the Bootp and tftp mode is enabled (see boot command), and
also as the default Server address to use for the update commands (default is
0.0.0.0). See note below.
gateway_ip= | gip=
This sets the Gateway IP address. This address is used when the Bootp mode is
enabled, default is 0.0.0.0. See note below.