Connecting Power
The Blue Heat/Net uses a standard DC power jack for power input. The Blue Heat/Net can be
safely connected or disconnected at any time. New BNG (RoHS compliant) models include the
additional option for 9 to 30V DC power input using a Phoenix locking screw terminal
connector. The standard power supply requirements are as follows:
Two port models
Models BN009, BN010, BN018
0.5A DC, 5 to 30 Volts unregulated.
Model BN009/10 with Power over Ethernet (PoE) and Screw terminal power
PoE: To use Power over Ethernet, the Blue Heat/Net must be connected to an IEEE 802.3af
compliant “PSE” Power Sourcing Equipment, such as a PSE Hub or PSE Switch
Screw Terminal Power: Use the provided Phoenix screw terminal connector Phoenix SMSTB 2,
5/2-ST-5.08 to power 36-56V DC. The power input is polarity independent. The acceptable
wire size is 14-24 AWG, 2.08-0.20 mm².
Four and Eight port models
Models BN001 to BN004
1A DC, 5 to 6 Volts unregulated.
Models BN005 to BN008
2A DC, 5 Volts regulated.
Model BNG008
2A DC, 5 Volts regulated.
Screw Terminal Power: Use the provided Phoenix screw terminal connector Phoenix MC 1,
5/2-STF-3, and 5 to power 9-30V DC. The power input is polarity independent.
Sixteen port models
Model BNG022
100-240VAC power input. Use an IEC-320-C7 style power cord suitable to your country.
Power cords for North America, the IK, Europe, Australia and New Zealand are available
from Connect Tech.
22-56VDC power input will accept 24-54 VDC +/- 5%. The ideal voltage range is 24 VDC to
48 VDC. A Phoenix Contact 1847055 two circuit screw terminal connector (included) or
equivalent must be used with this product.
Power Connector:
Figure 5: Power connector illustration.