CS – 4001/127 TMC – 4001/63 Capacity Test Equipment Manual G. Jost – electronic . Larstr. 55 . 53844 Troisdorf . Germany . www.battery-testing.
August 2006 CS–4001 Manual Page 2 CONTENT 1. 2. 3. 4. 5. 6. 7. 8. Safety precautions........................................................................................... 3 Panel CS-4001/127 ........................................................................................... 4 Panel CS/TMC-4001/63 and /31....................................................................... 5 Connection of the battery to CS/TMC-4001 ...................................................
August 2006 CS–4001 Manual Page 3 1. Safety precautions Before you begin to deal more deeply with the device itself we would like to give you a few safety hints in advance. Please observe the respective DIN/VDE/EN/IEC/ANSI-guidelines, the rules and regulations for local operators and the instructions of the battery manufacturer.
August 2006 CS–4001 Manual 2.
August 2006 CS–4001 Manual 3.
August 2006 CS–4001 Manual Page 6 4. Connection of the battery to CS/TMC-4001 Attention! The measuring cables must be connected to the TMC-4001 first, BEFORE being connected to the battery! 1) Power-up the CS/TMC-4001 and start the TMC95 or TMC4001-Light Software on your computer. 2) Connect the first measuring cable (multi-cable) to the connector C1 of the CS/TMC-4001. 3) Take the first crocodile–clamp (labelled with “1”) and connect it to the electrical minus pole of the battery.
August 2006 CS–4001 Manual Page 7 5. Removing the connections from CS/TMC-4001 First you must disconnect all crocodile-clamps from the battery. Next you can remove the connections C1 to C8 from CS/TMC-4001. You must not switch off the CS/TMC-4001 before all connections are removed from the battery. 6. Technical Data No.
August 2006 CS–4001 Manual Page 8 7. Trouble shooting You may have the USB-cable connected to the device, before the CS-4001 has been powered up. Remove the USB-cable and power up the CS-4001 again. You have MISCONNECTED the battery to All measuring cables are connected, but CS/TMC4001. Make sure that the first measuring when scanning only about –0.100V or cable (Connector C1) is ALWAYS connected to the negative voltages are displayed. electrical minus pole of the battery.
August 2006 CS–4001 Manual 8. The new DISPLAY PANEL The CS-4001/127 is equipped with our new LINUX board with TFT-Display and advanced communication facilities. The menu functions can be selected by turning the rotary button. The selected function is activated by pushing down the rotary button. The full function of this user interface will be implemented with our new CS-Manager software, which will be available around October 2006.