Specifications
Table Of Contents
- Imprint
- Documentation Representative
- © HYDAC FILTER SYSTEMS GMBH
- Contents
- Preface
- Safety information
- Storing the CS
- Decoding the model code label
- Checking the scope of delivery
- CS1000 Features
- CS1000 Restrictions on use
- CS1x1x dimensions (without display)
- CS1x2x dimensions (with display)
- Hydraulic connection types
- Fastening / mounting the CS1000
- Display rotatable/Adjustable As Needed
- CS1000 hydraulic installation
- Electrical connection of the CS1000
- Setting the measuring mode
- Operating the CS1x2x using the keypad
- Overview of menu structure
- Using switching output
- Setting limit values
- Reading the analog output
- Status Messages
- Connecting CSI-D-5 (Condition Sensor Interface)
- Connecting the CS1000 to an RS-485 bus
- Communicating with the CS1000 via the RS-485 bus
- Taking the CS1000 out of operation
- Disposing of CS1000
- Spare Parts and Accessories
- Cleanliness classes - brief overview
- Checking/resetting default settings
- Technical data
- Recalibration
- Customer Service
- Model Code
- EC declaration of conformity

ContaminationSensor CS 1000 Status Messages
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 88/112
BeWa CS1000 3764916 300 en-us 2012-08-29.doc 2012-08-29
LED Blink code /
Display /
Analog output /
Switch out
Status To do
Error
no.
Red
2%2$2§
2DIRTY
19.9 mA / 9.95 V*
Open
The sensor is above
its measurement
range ISO 25/24/23.
It is not possible to
determine the flow
rate.
Filter the fluid.
3
Exceptions Errors
LED Blink code /
Display /
Analog output /
Switch output
CS1000 Status To do
Error
no.
OFF
0 mA / 0 V*
Open
CS
no display
no function.
Check the supply
voltage for the CS.
Contact HYDAC.
-
Red
2 LOW
4.1 mA / 2.05 V* or
19.9 mA / 9.95 V
Open
"2 low" on "Drive"
If the CS is supplied
with 24 V, then
reduce the supply
voltage to 12 V. If the
error persists, contact
HYDAC.
-