Specifications

Table Of Contents
ContaminationSensor CS 1000 Using switching output
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 52/112
BeWa CS1000 3764916 300 en-us 2012-08-29.doc 2012-08-29
Using switching output
You can use the switching output in the modes described below. For a further
description of the measurement modes, see page 28.
Mode M1: Continuous measurement
Purpose: Measurement only
Function: Continuous measurement of cleanliness class Switching function
only for "Device ready".
Mode M2: Continuous measurement and switching
Purpose: Continuous measurement and controlling of signal lamps etc.
Function: Continuous measurement of solid contamination, continuous
monitoring of programmed limit values; the switching output is
enabled and switches on the monitoring display or alarm on site
Mode M3: Filter to cleanliness class and stop
Purpose: Clean up hydraulic reservoir
Function: Control of a filter unit, continuous measurement of solid
contamination. If pre-programmed cleanliness level is reached 5
times in sequence, the pump is stopped.
Mode M4: Filter to continuously monitor cleanliness class
Purpose:
Establish continuous monitoring of cleanliness class between
min/max limit values
Function: If min/max limit values are pre-programmed, the CS switches the
filter unit on/off to keep cleanliness within the limit value range
Load the switching output with a maximum of 2 A and 30 V DC.
Mode "SINGLE" measurement
Purpose: Perform a single measurement and "stop" the result.
Function: Single measurement of solid contamination without switching
functions Switching function only for "Device ready".