Setting the measuring mode
Once the sensor is switched on or supplied with power, it automatically runs in the
measuring mode that has been set.
Mode M1: Continuous measurement
Application: Stand-alone sensor
Data output: Display & RS485 & analog output
Purpose: Measurement only
Function: Continuous measurement of cleanliness class Switching
function only for "Device ready".
Mode M2: Continuous measurement and switching
Application: Stand-alone sensor with alarm standby display
Data output: Display & RS485 & analog output & switching output
Purpose: Continuous measurement and controlling of signal lamps etc.
Function: Continuous measurement of solid contamination, continuous
monitoring of programmable limit values; switching output is
activated to switch on the monitor display or an alarm on site
Mode M3: Filter to cleanliness class and stop
Application: Controlling a filter unit
Data output: Display & RS485 & analog output & switching output
Purpose: For cleaning up a hydraulic reservoir
Function: Control of a filter unit, continuous measurement of solid
contamination. If pre-programmed cleanliness level is achieved
5 times in sequence, the pump is stopped.
Load the switching output with a maximum of 2 A and 30 V DC.