Selecting the measurement point
In order to obtain cleanliness values that are continuous and coherent in real time,
select a suitable measuring point according to the following guidelines:
A
B
2
A
B
1
3
A
2
1
B
WRONG WRONG OK
1
Select the measurement point so that the sample measured comes from a
turbulent location, with a good flow. For example: on a pipe elbow, etc.
2
Install the sensor near the measurement point to achieve as timely results
as possible.
3
During installation, avoid creating a "siphon" trap for particle deposits in the
line (sedimentation).