Product Info
Connect™ Monitor Instructions Manual
AUGUST 2020
7
Physical Installation
Position and Location
For optimum operation, the choice of physical location and position of the Connect Monitor should meet all
the following criteria.
FOR COOLERS WITH EVAPORATORS LOCATED AT THE TOP OF THE CABINET:
Connect Monitor must be mounted BELOW the
evaporator inlet, preferably ABOVE the top shelf.
Connect Monitor works best when mounted on the side
wall on the HINGE side of the cooler.
When possible, mount Connect Monitor
away from LED panels to improve
temperature measurement accuracy.
Hinge side placement reduces the visual
impact and likelihood of Connect Monitor
being accidentally knocked out of place.
This ensures the Connect Monitor reads the
return air temperature correctly.
Installation ABOVE the evaporator inlet
may result in incorrect temperature reading
due to placement in an air circulation dead-
space that is often different to the cabinet
temperature.
If installation in accordance to the below conditions proves to be challenging, please
contact your WDTL representative to review appropriate recommendations.