Service manual
82
Installing New Refrigeration System
Turn off electrical power to oven before servicing.
WARNING :
CAUTION :
Refrigeration System is heavy. Use proper lifting
techniques when moving system.
When installing new Refrigeration System take the same steps as the removal
process only in reverse. Any other differences are listed below and should be
followed to ensure proper installation of system.
Once the new system is in place and secured to unit, ensure gaskets around duct
transition boxes are sealed.
Duct and transition box insulation must be positioned to their original location and
sealed with Polyken® 360-17 FOILMASTER™ Sealant U.L. 723 approved tape,
or equivalent. Standard foil tape should not be used.
Double-check all wire connections to ensure they are secured and routed
properly. Avoid pinching or damaging wires.
When reinstalling rear covers, ensure there are no wires pinched between covers
and unit.
Replace Refrigeration panel, see (Fig. 12).
1.
2.
3.
4.
5.
6.
Female locking tab
Male locking tab
Fig. 12