Service manual

53
Removing Damper Motor
First, loosen the Damper set pin inside
the damper box. Access the set pin
from front of the refrigeration vents
inside oven cavity, see (Fig. 1). If set
pin is not visible, the damper is not in
the correct position and pliers should
be used to grip damper shaft to rotate,
see (Fig. 2).
Damper should be positioned as shown
in (Fig. 3).
Use an allen wrench to loosen the set
screw through refrigeration slots inside
oven cavity. Pin only needs to be loose.
NOTE: Do not remove pin, doing so
could cause pin to fall and require
further disassembly of unit.
1.
2.
3.
Fig. 1
Fig. 2
Fig. 3
Front View
Turn off electrical power to oven before servicing.
WARNING :
CAUTION :
Sheet metal parts could have sharp edges and corners.