Installation Instructions
Expansion by Congoleum
Expansion Installation
Choices
Your Choice Plus Installation System AS01 Adhesive QuikStik Tape
Loose Laid (Seams) Yes Yes
Perimeter Fastened Yes Yes
Fully Adhered Yes No
Expansion by Congoleum is manufactured on Congoleum
Fibrous Felt Inner Layer and Dense Flexible Vinyl
Composite
Backing.
Expansion by Congoleum is a 15’ wide flexible floor that
features UltraTec construction. This construction
provides controlled stability and eliminates curl allowing
the flooring to be installed by the Your Choice Plus
Installation System which includes the fully adhered,
perimeter fastened and loose lay installation methods.
Depending on the method used, the floor can be
installed with UnderFlor AS01 adhesive or QuikStik Tape.
RECOMMENDED APPLICATIONS:
The best method for a particular job depends on the
subfloor conditions. For example, the fully adhered
method is recommended where the subfloor is smooth,
structurally sound and free of movement, in a variety of
applications including complex room layouts or where net
fitting or coving is required.
The perimeter fastening and loose lay methods provide
subfloor masking benefits to allow installation over a
greater variety of surfaces that might otherwise be
unsatisfactory
for a fully adhered application.
The loose lay method is recommended for room layouts
where trim can be installed around the entire perimeter.
The perimeter fastening method can be used for most
applications and it provides not only subfloor masking
benefits, but also provides the option to fit flooring net
where it is not desirable to install trim.
GENERAL INFORMATION
Recommended
Installation Accessories
• UnderFlor AS01 Adhesive (For all installations) or TEC
Premium Sheet Vinyl Adhesive
• QS120 QuikStik Tape (For loose lay at seams and for
perimeter installations)
• SU80 Seam sealer or Tarkett DT-65 Low Gloss sealer
Recommended
Use
• Residential
applications
on all grade levels
• Interior use in dry, heated areas
• Do not install over ramps, in showers or other wet areas
Installation Temperature
Congoleum residential sheet flooring is designed to be
installed in enclosed, heated areas only where HVAC has
been in operation for at least 7 days prior to installation
and thereafter.
For best results the sheet flooring should be installed at
the same temperature as the room(s) will be when
occupied or in service. The subfloor, all flooring material,
and adhesive must be conditioned at a constant
temperature between 65°F (18°C) and 85°F (29°C) for 48
hours before, during and 48 hours after installation.
Thereafter, maintain room temperature between 55°F
(13°C) and 100°F (38°C).
Handling and Storage
Roll all Congoleum sheet products face out, wrapped
tightly around a rigid core with a minimum 4” diameter
until ready for installation. Store and transport the roll on
a flat surface with continuous support in a clean, dry,
interior area where it is protected from the elements.
Ideal long-term storage temperatures range from 50°F
(10°C) to 70°F (21°C).
Avoid stacking other heavy rolls or objects on rolls that
can crush or distort them. Always handle rolls carefully to
avoid damage.
RECOMMENDED SUBFLOORS AND PREPARATION
Suitable Substrates
Congoleum sheet products are recommended for
installation over properly prepared suspended wood
floors and approved underlayments, concrete on all grade
levels, metal, terrazzo, ceramic and marble. The substrate
must be clean, dry, smooth, structurally sound, and free
of curing compounds, parting agents, old adhesive, paint,
varnish, oil, grease, wax, solvent and other foreign
material than can affect the flooring or interfere with the
adhesive bond.
Wood Floors must be double layer construction for fully
adhered installations, or single layer approved subfloor
panels for perimeter or loose lay installations, structurally
sound and free of movement with at least 18” (46 cm) of
well-ventilated air space below. Sand joints smooth and
set fasteners 1/32” (.8 mm) below the surface. Rough,
weathered or damaged subfloor panels must be sanded
smooth or covered with a suitable underlayment panel.
Fill underlayment joints wider than 1/32” (.8 mm).