- 2 -
Additional Properties and Performance Specifications
ASTM F970 Static Load Limit
Passes – Exceeds 2,500 psi
ASTM E648 Critical Radiant Flux
Passes - ≥.45 watts/cm², Class 1
ASTM E662 Smoke Density
Passes - < 450
Slip Resistance
ADA Compliant
HUD/FHA Requirements
Exceeds
Limited Commercial Warranty
10 Years
Recommended Adhesives
Congoleum AD32 Adhesive (pressure sensitive)
Congoleum AD62 Adhesive (wet set) Must be used when
heavy static or rolling loads are present or where high
performance requirements must be met
Structure is not recommended for use on ramps, in commercial areas that require static dissipative
flooring, or in commercial areas where the surface temperature over radiant heated substrate exceeds
85° F. Structure is intended only for indoor applications.
Architectural Specification
All floors shown in the finish schedule or listed in the specification shall be Structure Luxury Solid Vinyl
Flooring provided by Congoleum Corporation, in design and color (list color(s) ___________) selected
from the range currently available from Congoleum Corporation, having a nominal total thickness of
0.120 in. (3.0 mm) gauge, and size in [48 in. x 9 in. (1219.2 mm x 228.6 mm)], consisting of a 0.020 in.
(0.5 mm) thick wear layer over a printed film on an intermediate layer over a filled vinyl backing. Flooring
is asbestos free and meets composition, size, thickness, squareness, flexibility, residual indentation,
resistance to chemicals, resistance to heat and resistance to light requirements of ASTM F 1700,
“Standard Specification for Solid Vinyl Tile,” Class III, Type B – Embossed Surface. The product shall
have a 10 Year Limited Commercial warranty against manufacturing defects. The adhesive shall be
Congoleum AD32 or Congoleum AD62 for use under heavy static or rolling loads or where high
performance requirements must be met.
For additional installation, maintenance, or technical information, visit our website at
www.congoleum.com or contact our Technical Services Department at 1-800-274-3266.
Please view actual product samples when making a selection as our printed colors may vary from actual
product.
Structure is certified under FloorScore, an independent 3rd party Indoor Air Quality certification program
for low emitting flooring. Structure is CHPS O1350 compliant and recognized as contributing to LEED
EQ Credit 4.3. Adhesives meet VOC content limit of SCAQMD Rule #1168 and may also contribute to
LEED EQ Credit 4.1. Structure and Congoleum adhesives can contribute points under the National
Green Building Standard (NAHB) ICC 7700-2008.
3500 Quakerbridge Road � Post Office Box 3127 � Mercerville, New Jersey 08619 � (609) 584-3000 � www.congoleum.com