Installation Instructions

DURACERAMIC INSTALLATION
Tile Layout
Layout is slightly different for grouted and ungrouted oors. The grout line
width must be added to the tile dimension for layout on grouted oors. Ad-
ditional chalk lines are also used to keep the joints straight. DuraCeramic
Origins nominal tile size is 15 5/8" x 15 5/8". DuraCeramic Dimensions
nominal tile size is 12" x 24". Ovations nominal tile size is 14" x 14".
It is important to avoid positioning the tile joints directly over underlayment
joints or seams in UnderFlor or existing ooring. If this should occur, repo-
sition chalk lines to offset joints by at least 3" or half of the tile dimension.
8
Suboor
Construction/ Comments Notes
Materials
Double layer construction over
joist or trusses on 16" or 19.2"
centers.
Single layer oors constructed
with APA Rated Sturd-I-Floor
T&G Panels, minimum 23/32"
over joists or trusses on
19.2" centers.
Underlayment
APA underlayment grade
plywood.
Oriented Strand Board (OSB)
NPA rated Particleboard
Concrete On, above and below
grade level.
Radiant-heated oors not
to exceed 85°F (29°C).
Minimum 100-pound
dry density
Minimum 3,000 psi
compression rating is required.
Smooth, or textured sheet
ooring
Vinyl composition tile
Do not install over soft, heavy
cushioned oors, ooring
with a cushioned backing
or tile installed below
grade below.
Ceramic, marble and granite.
Adhesive Residue - Scrape to
remove heavy spots and cover
with a 4 mil sheet of poly lm.
Paint - Remove loose paint.
Congoleum UnderFlor & QuikStik UnderFlor
Substrate Recommendations
UnderFlor & QuikStik UnderFlor can be installed over the following surfaces:
Suboor must be
smooth solid and
free of movement
with at least 18" of
well ventilated air
space below.
Weather damaged
or rough surface
materials must be
sanded smooth.
Gaps wider than
1/8" should be
lled level.
Moisture vapor
emissions not to
exceed 5 lbs. or
80% RH. Fill depres-
sions and cracks
wider than 1/8".
Fill depressions
and cracks wider
than 1/8".
Resilient
Floor
Must be single
layer, fully adhered
and well bonded.
Fill grout joints
and level oor.
Ceramic
and Stone
Old Adhesive
and Residue
and Paint
Follow recom-
mended work
practices for
adhesive and
paint removal.
Gypsum
Topping and
Light Weight
Concrete
Wood
Structure
Important:
For tile installation, QuikStik Underor must be positioned in the
room with seams at least 4" away from the joints in the nished oor
tile. (Figure 1).
For DuraCeramic Dimensions always install QuikStik UnderFlor
with seams running perpendicular to the long dimension of the tile
ooring
(Fig. 2). Install tiles with staggered end joints positioned at least
4" away from the seams in the Congoleum QuikStik UnderFlor.
Install QuikStik Underor with the felt side down.
Unroll the rst sheet and trim to t allowing 1/8" to 1/4" space
between the edge of the sheet and the wall.
Unroll the second sheet and position it with the seam edge butted
lightly against the rst sheet.
The pre-applied adhesive layer stops about 1 1/8" from each edge.
This allows you to butt the edges together and apply the double
face tape (included in the carton) along the edges without having to
pull back the release liner.
Always roll the seam tape with a hand roller to rmly embed it.
Minor rips or tears can easily be xed by simply pulling back the
release liner on either side of the tear and applying a piece of the
seam tape to the torn area.
Fig. 1 – Position QuikStik Underflor seams at least
4” away from tile joints.
QuikStik
Seams
Fig. 2 – Install QuikStik UnderFlor with seams
perpendicular to the long dimension of the
DuraCeramic Dimensions flooring.
58