Installation Instructions
Suboor 
Construction/ Comments  Notes 
Materials
Congoleum
  • UnderFlor and QuikStik UnderFlor are 
underlayment systems for oating  
installations of DuraCeramic Origins, 
DuraCeramic Dimensions and Ovations 
over a variety of substrates in lieu of 
direct bonding. See detailed 
instructions on page 7.
Wood
  • Double layer construction over joist 
or trusses on 16" or 19.2" centers with at 
least 18" of well-ventilated air space.
  • Install 1/4" or heavier underlayment 
over strip wood, single layer wood oors  
and APA-rated Sturd-I-Floor Systems.
Underlayment
  •  APA underlayment grade plywood 
with fully sanded face.
  • Hardwood and veneer 
underlayment panels.
  • Lauan plywood, particleboard, 
oriented strand board and chipboard 
create a higher risk for installation 
and adhesive failure and are not 
recommended unless warranted by 
the panel manufacturer or supplier.
  • Not recommended over cement 
backer-boards, glass mesh mortar 
units or acoustical cork.
Concrete
  • On, above and below grade level.
  • Radiant-heated oors not to 
exceed 85°F (29°C).
  • Minimum 100-pound dry density
  • Installation over gypsum-based 
acoustical toppings is not 
recommended unless Congoleum 
UnderFlor or QuikStik UnderFlor is used.
  • Smooth, non-cushioned sheet 
ooring and vinyl composition tile.
  • Embossed non-cushioned and thin 
cushioned vinyl ooring can be 
prepared with embossing leveler 
in residential applications.
  • Do not install over soft, heavy 
cushioned oors, ooring with a  
cushioned backing, self-adhering 
tile or tile installed below grade level.
  • Ceramic, marble and granite. 
  • Not recommended.  Remove 
  • Portland cement-based compound 
such as Ardex Feather Finish, 
Mapei Plani-Patch or equal.
  • Gypsum-based patching 
compounds are not recommended.
Congoleum UnderFlor
UnderFlor is an all-in-one underlayment system that provides 
an economical solution for installing DuraCeramic Origins, 
DuraCeramic Dimensions and Ovations as a oating ooring 
system over a variety of suboor surfaces. Now, one under-
layment covers it all; wood, concrete, most old hard surface 
ooring, gypsum topping, even old adhesive residue and 
painted surfaces. 
Congoleum UnderFlor is constructed in 6’ wide rolls, and 
since it is a oating underlayment, it requires no fasteners or 
special tools so it’s quick and easy to install.
Roll Sizes
UF120 – 6' x 180' (120 sq. yds. or 1080 sq. ft.)
UFB07 – 6' x 16.7' (11.11 sq. yds. or 100 sq. ft.)
Recommended Use
• Residential applications on all grade levels
• Interior use in dry, heated areas
• Do not install over ramps, in showers or other wet areas
General Information
•  Always roll sheets of Congoleum UnderFlor tightly around a 
tube with the vinyl side out for storing and transporting. 
Avoid distorting Congoleum UnderFlor.
• Condition the room and all ooring materials at a constant 
temperature between 65°F (18°C) and 85°F (29°C) for 
48 hours prior to, during and 48 hours after installation.
•  All UnderFlor underlayment and nished ooring must be 
installed with a 1/4" space around the perimeter of the room 
to allow for expansion and contraction of the ooring system 
and suboor. Undercut door casing and slide nished oor-
ing under for a nished appearance. 
• Use DS100 Adhesive only for installing Congoleum 
DuraCeramic Origins, DuraCeramic Dimensions and Ova-
tions over Congoleum UnderFlor. Hard setting adhesives 
should not be used with Congoleum UnderFlor. 
Congoleum UnderFlor Installation
Install Congoleum UnderFlor with the vinyl side down just 
prior to installation of nished ooring. Determine the ap-
propriate seam location and direction of the underlayment 
(depending 
on the nished ooring selection). 
Important 
For tile installation, position UnderFlor with seams at least 4" 
away from the joints in the nished oor tile. (Fig. 4).
Fig. 4 – Position seams at least 4" away 
from tile joints.
The suboor 
system for 
oating surface 
must be 
smooth, solid 
and dry. 
Suboor must 
be solid and 
free of move-
ment.
Install according 
to panel manu-
facturers’ written 
instructions.
Moisture vapor emis-
sions not to exceed 5 lbs. 
or 80% RH.
Conrm  
adequate 
adhesion to 
substrate.
Light Weight 
Concrete  
(Residential 
Application only)
Resilient 
Floor 
(See WARN-
ING on inside 
cover)
Must be single 
layer, fully adhered 
and well bonded. 
Remove wax or 
polish.
Fill grout joints 
and level oor. 
Ceramic 
and Stone
Carpet/ 
Laminate
Patching 
Compound
Refer to manufac-
turers’ instructions 
for use and 
applications.
Suboor Recommendations
6
UnderFlor 
or QuikStik 
UnderFlor
56










