User's Manual

4-5
Absolute Maximum Ratings Operating Conditions
Supply Voltage..........................-0.3Vto4.0V(Max)
StorageTemperature(Note4).................. -20
o
Cto85
o
C
TemperatureRange........................ 0
o
C T
A
70
o
C
Supply Voltage Range . .........................3.0Vto3.6V
Caution: These are the absolute maximum ratings for the PC Card product. Exceeding these limits could cause permanent damage to the card.
NOTE:
4. All temperature references refer to ambient conditions.
Electrical Specifications Test Conditions: Supply Voltage (V
CC
) = 3.3V, Ambient Temperature (T
A
)=25
o
C,
Unless Otherwise Specified
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
CURRENT CONSUMPTION
Initializatoin Current I
CC
- 145 180 mA
Average Current
(With Power Saving Mode) (Note 5)
I
CC
-TBD - mA
Continuous Transmit Mode I
CC
- 325 380 mA
Continuous Receive Mode I
CC
Receiving Valid Packets - 200 225 mA
Standby (Note 5) I
CC
-TBD - mA
PC CARD LOGIC LEVELS
Input HIGH Voltage V
IH
V
CC
=Max, Min 0.7V
CC
-- V
Input LOW Voltage V
IL
V
CC
=Min, Max - - 0.3V
CC
V
Output HIGH Voltage V
OH OL
=2mA,V
CC
=Min 0.9V
CC
2.6 - V
Output LOW Voltage V
OL
I
OL
=2mA,V
CC
=Min - 0.05 0.1V
CC
V
Input Leakage Current I
I
V
CC
=Max, Input=0V or V
CC
0.100 1.0 µA
PC CARD LOADING CAPACITANCE
Input Capacitance C
IN
- 5 10 pF
Output Capacitance C
OUT
- 5 10 pF
ENVIRONMENTAL SPECIFICATIONS
Vibration Vib 10 to 2000Hz, V
CC
=0 - - 15 G
Shock Shock - - 50 G
Drop Drop - - 75 cm
Torque T 10
o
Max - - 1.236 N-m
ESD ESD Non-Operating - - 1500 V
X-RAY X-RAY - - 10 Roentgen
UV UV Wavelength 254nm - - 15K µW/cm
2
Humidity RH Method 106E Mil-Std 202 - - 98 %
EMI EMI - - 1K Oersted
RF SYSTEM SPECIFICATIONS
Transmitter Power Output P
out
- +11.5 - dBm