9. Type 1 for 6500 mode or 2 for SIA mode and
press [ENTER] to enter the selection.
6.0 Configuring for D6100i
Network Communication
The following steps allow the D6100i to communicate
with the host PC running the D6200 Programming
Software.
10. Press [CANCEL] and scroll down [] to
6.3.7 Device.
For the network communication to
11. Press [ENTER].
function, install a properly configured
D6100i. Refer to the previous sections.
12. Press [1] for automation communication through a
network, or [2] for automation communication
through the RS-232 COM3 port.
If network communications are not
installed, further D6200 software
programming using the network is not
possible.
13. Press [CANCEL] and scroll down [] to 6.4 D6200
Network Connections.
1. On the D6100i keypad, press [MENU] and enter
the default passcode of [6][1][0][0] to enter the
programming mode. Press [ENTER] again.
14. Press [ENTER] to move to 6.4.1 IP Address 1.
15. Press [ENTER] again to enter the IP address of
the host PC that runs the D6200 Software.
To change any programming
parameter, follow this syntax:
• Press [ENTER],
• Enter the desired value,
• Press [ENTER] again to store the
value.
2. Scroll down [] to 6 NETWORK
CONFIGURATION and press [ENTER].
3. Scroll down [] to 6.2 Network Adapter and press
[ENTER].
6.2 COM4 Network Adapter
4. Set 6.2.5 Network Adapter Enabled to a value of
1 and press [ENTER]. If the value is not 1, press
[ENTER][1][ENTER].
6.2.5 COM4 Network Adapter Enabled
Current setting [1]
5. If the D6100i has encryption enabled, Set 6.2.6
Network Encryption Enabled
to 1.
6. Press [CANCEL] and scroll down [] to
6.3 Network Automation Connection.
6.3 Network Automation Connection
7. Press [ENTER].
8. Scroll [] to 6.3.6 Network Automation Output
Format.
When entering an IP address through
the keypad of the D6100i, press an
alpha character ([A] to [F]) to enter a
decimal point in the IP address.
For example, enter IP address 202.96.168.127
as:
[2][0][2][A][9][6][A][1][6][8][A][1][2][7][ENTER].
16. Scroll [] to 6.4.5 Network Programming Enable.
Verify that the value is 1. If the value is not 1,
press [ENTER][1][ENTER].
17. Press [CANCEL] repeatedly to return to the idle
stage (time and date show on the LCD).