Conettix D6600/D6100i System Guide EN Network Communications
D6600 | System Guide | Contents Contents 1.0 1.1 2.0 2.1 2.1.1 2.1.2 3.0 3.1 3.2 3.3 3.3.1 3.3.2 3.4 3.4.1 3.4.2 3.4.3 3.4.4 4.0 5.0 5.1 5.2 5.3 5.4 5.4.1 6.0 2 Introduction........................................................................................................................................... 3 Other Literature Referenced ................................................................................................................ 3 Overview...........................................
D6600 | System Guide | 1.0 Introduction . 2.0 Overview Trademarks Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc.
D6600 | System Guide | 2.0 Overview Table 2: Network Adapters Part Numbers Part Number D6680-E120 ITS-D6682-UL ITS-D6682-INTL Application Description Ethernet Network Adapter D6682 supplied with a UL-approved transformer (Group West/Part number 48D-12-900). D6682 supplied with a international power supply with regional adapters All alarm panels (from Bosch or other manufacturers) using the Conettix D6600/D6100i Network System must have an interface (as described above) to allow for network reporting.
D6600 | System Guide | 2.0 Overview .
D6600 | System Guide | 3.
D6600 | System Guide | 3.0 Operation . If the host computer is running Windows XP, 2000, Vista, or Windows 7 and is new to the network, you must perform the following steps: 5. Scroll in the Components checked are used by this connection: list and select Internet Protocol (TCP/IP). Although the screen captures in this procedure are specific to Windows 2000, they are similar for Windows XP, Vista, and Windows 7. 1. Select Start Æ Settings Æ Control Panel. 2.
D6600 | System Guide | 3.0 Operation You must enter the correct subnet mask and gateway for all devices that are on this network. Contact the network administrator for these values. 8. If necessary, copy the requested files to the computer. This might require Microsoft Windows operating system disk for the version you are using. 9. After copying the files, you might need to restart the PC. If so, connect the host PC’s NIC card to the network (hub) and restart the PC. 10.
D6600 | System Guide | 3.0 Operation . 15. Select the Hardware tab. 21. Select the Port Settings tab 16. Click the Device Manager button. 22. Select 38400 bits per second baud rate from the Bits per second: drop-down menu, then click OK. A hardware tree appears showing all the devices connected to the PC. 3.2 17. Click the plus sign ( ) next to Ports (COM & LPT) to reveal the individual ports. 18.
D6600 | System Guide | 3.0 Operation Figure 5: D6680/D6682 Connection Do not connect both D6680s/D6682s to the network at the same time. 4. After completing these settings, you must do two additional settings: 1234567- D6600 Number 1 D6600 Number 2 Null modem cable D6680/D6682 Number 2 A/B Network switch Network switch D6680/D6682 Number 1 In Figure 5, another necessary programming parameter is an Alternate MAC Address.
D6600 | System Guide | 3.0 Operation . To use this datagram type, program it in the following order: 1. Confirm that D6200 version 1.20 or later is installed. 2. Confirm that the D6600 CPU version 01.02.01 is loaded in the receiver. 3. With the D6200 software, select Network Æ Network Configuration Management Æ Read/Manage Network Configuration from Receiver. 3. At the Port Number selection, enter a source port that is not being used by another NIM on the same network (such as 7701, 7702, 7703, and so on).
D6600 | System Guide | 3.0 Operation 3.4 Networking and Encryption If you are considering using or are currently using networking and encryption, read the following information carefully. In all cases, encryption is performed in the NIM (Network Interface Module) that is used in the D6680/D6682, D9133TTL-E, C900V2/C900TTL-E, and DX4020. When encryption is used, the encryption key coming to the D6600 must be the same key used on all field devices that are reporting to that IP address.
D6600 | System Guide | 3.0 Operation . You can have two D6680s/D6682 on one D6600, one with encryption On and the other with encryption Off. This setup would allow for field devices to continue to communicate with the D6680/D6682 with encryption Off and begin the programming of the field devices to send with encryption On to the second D6680/D6682. This would allow devices to be programmed for encryption without the loss of any signals or data to the D6600.
D6600 | System Guide | 4.0 Special Conettix D6600 Applications 4.0 Special Conettix D6600 Applications The following special application has been requested by Bosch dealers. It is included here to assist you if you have the same requirement. If you have any questions, contact Technical Support at (800) 289-0096. Emulating a Direct Serial Connection Over a LAN Using D6680/D6682 Ethernet Network Adapters Some applications might require a direct serial connection be emulated over the network.
D6600 | System Guide | 5.0 D6100i Configuration Setup Instructions . 5.0 D6100i Configuration Setup Instructions 5.1 Identifying the MAC Hardware Address You must program the IP address of the D6100i. The first step is to determine the MAC, or hardware, address of the D6100i. This address is hard-coded into the D6100i during its manufacture and cannot be changed. This address is 6 bytes (12 digits) long. The following procedure shows how to use the ARP command to assign an IP address to the D6100i.
D6600 | System Guide | 5.0 D6100i Configuration Setup Instructions This command displays the IP address 172.17.10.70 temporarily linked to MAC address 00-20-4a-12-04-0e as shown in Figure 8. The temporary link shows a static entry. Figure 8: ARP Table By default, Windows Vista does not install the Telnet client. The Telnet client is for text-based communication with remote systems. To install the Telnet client on a PC running Windows Vista: 1. Click Start→Control Panel. 2. Select Programs and Features. 3.
D6600 | System Guide | 5.0 D6100i Configuration Setup Instructions . 5.4.1 Configuration Using Telnet The following prompt appears: 1. Type 0 (zero) and press [ENTER] to set up the basic server configuration. If the D6100i was previously programmed with an IP address, the address appears in parentheses. 2. Type the IP address (for example, 190.200.128.219) and press [ENTER]. 3. If the Gateway address is required, type y, press [ENTER] and then type the address and press [ENTER].
D6600 | System Guide | 5.0 D6100i Configuration Setup Instructions 8. At the I/F Mode prompt, press [ENTER] to accept the default (4C). 9. At the Flow prompt, press [ENTER] to accept the default (00). 10. Type a unique Port Number for the LAN to which the D6100i is connected and press [ENTER]. 11. At the ConnectMode prompt, press [ENTER] to accept the default (CC). 12. At the Datagram Type prompt, type 00 or 02 and press [ENTER]. 13.
D6600 | System Guide | 6.0 Configuring for D6100i Network Communication . 6.0 Configuring for D6100i Network Communication The following steps allow the D6100i to communicate with the host PC running the D6200 Programming Software. For the network communication to function, install a properly configured D6100i. Refer to the previous sections. If network communications are not installed, further D6200 software programming using the network is not possible. 1.