Specifications

Table Of Contents
56
Should the display remain dark for a longer period of time after sunrise
you must check the no-load voltage of the solar modules.
Should the no-load voltage of the modules (at the connecting points of the
Conergy WR unit) not reach 160 V, it is possibly the case of a defect in
the remaining part of the photovoltaic system.
If the no-load voltage of the solar modules (at the connection points of the
Conergy WR unit) amounts to more than 160 V, there may be a basic
defect in the Conergy WR unit. In this case you must consult a trained
service technician.
Complete
failure
After a short time of waiting the Conergy WR resumes network synchroni-
zation (message: „SYNC
AC
“).
As long as the power output at the solar modules is insufficient, the dis-
play shows the message „POWER
LOW
“.
General ser-
vice codes
(continued)
Display in normal operation
(D)
Fault in one of the two power stage
sets:
- Display of a service code (e.g.
„State 515“)
Abwechselnd
(D)
Important! The display of the
service code alternates with „En-
ter“.
- Press „Enter“ key twice
(D)2x
Conergy WR
with several
power stage
sets
A special status diagnostic is run if an error occurs in a Conergy WR with
several power stage sets. The examples shown below illustrate the trou-
ble-shooting process.
Important! It is also possible to call up status messages even if there is
no actual error in existence. This form of status polling may be found in
the set-up menu.
1