Specifications

Table Of Contents
10
The complex technical systems of innovative solar inverters make it ne-
cessary to design the display which is the interface with the user very
carefully. It is an unwavering design aiming at ease of operation and
permanent availability of the system’s data.
The Conergy WR unit is equipped with a basic recording function for
monitoring minimum and maximum data on a daily and a cumulative
basis directly from the display. There is also an option to allow the reading
of the following weather data on the display:
- two different temperature readings (for example temperature at the
solar modules as well as the outside temperature in the shade)
- insolation
In additition to the functions installed in the Conergy WR unit, a wide
choice of elements offered for data communication allows for many possi-
bilities of recording and visualising data. The respective components
required to upgrade the system are easy to install using the IG DatCom
operating instructions. The installation of system upgrades, such as Dat-
Com components, allows for possible remote system monitoring via mo-
dem, text messages to mobile phones in the event of faults, data visuali-
sation and data comparison on the PC.
Display func-
tion and data
communicati-
on
The Conergy WR unit is in charge of monitoring the mains network. This
responsibility comprises all measures necessary for the protection of
persons and machines in case of a power blackout.
The Conergy WR unit is programmed to stop operation immediately and
stop supplying power whenever conditions in the mains network deviate
from standard (for example when power is switched off or in case of any
other kind of interruption).
There are several ways how the Conergy WR unit can identify a mains-
cutoff, it can do so for example by monitoring:
- voltage
- frequency
- resistance (only Conergy WR with ENS)
For this purpose it is important that the specific monitoring procedures
applicable for the respective countries are carried out directly by the Con-
ergy WR unit without the use of additional electronic monitoring devices.
This will result in a substantial reduction of the installation work and cost.
Monitoring the
mains network
The Conergy WR is equipped with an HF-transformer (HF = high frequen-
cy) which assures a galvanic insulation between the DC side and the
mains. In addition, the HF principle results in a drastic reduction of the
transformer’s size, which means that it requires less space and has consi-
derably less weight. In spite of its full galvanic insulation, the Conergy WR
unit achieves a high degree of efficiency, due to its innovative circuit sche-
mes.
Voltage trans-
formation and
galvanic insu-
lation
(continued)