Installation manual

ENGLISH
Conergy AS
Owners Manual
7
Your Conergy Split System model number
System operation
A Conergy solar water heater is designed for fully automatic operation, so there is nothing you need
to do for day to day system operation. If the AES System has been fitted with a remote isolator switch
or time-clock, you may make the decision when and if Ancillary Energy Support is permitted. As a
guide you may like to isolate the AES System during the summer months and you may use a time clock
to permit boosting after sunset or any other combination, which suits your usage pattern. Careful use
of these options can further reduce your energy use for hot water supply to the household.
collector temperature rises above 190°C, the circulation pump will be initiated to reduce the
collector temperature to below 185°C. This is to protect the collector from prolonged periods
of extreme temperature.
System Cooling. During the collector circuit temperature control operation, if the storage tank
water temperature has risen above the set 70°C maximum, the controller will initiate the pump
to reduce the excess tank temperature back to the set point of 70°C. This function is to ensure
water temperatures above 70°C are not stored for prolonged periods in the storage tank.
5.
1.5
1.6
1 Owners Information
XX NNN / N / X / XNN / X / XNNXX
System Type - Nominal Volume - Collector Area - Tank Type - Booster - Tank Material - Collector Type
Variable Categories
System Type AS Active Systems (pumped)
HP Heat Pump System Type
TS Thermosiphon, TS
Nominal Volume Nominal Storage Volume
Collector Area 2, 2.5, 4, 5, 6 Nominal Collector Area
Tank Type O Open Circuit
C Closed Circuit
Booster E Electric
G Gas
XX Booster Rating (kWx10 or Lpm)
Tank Material /
Designation
V Vitreous Enamel
S Stainless Steel
M Millenium Tank
Collector Type E20SB, E20BC, E25BC or F20LC