7 Electrical Connections to the System
7.3.1 Controller field settings for the Deltasol B solar controller
It is not recommended that you alter the optimal factory settings or run the system in manual
for extended periods. Changes in settings may adversely affect solar performance.
Use Buttons 1 & 2 to scroll through the values. The elds should match the values in the table
below.
If there is a need to change a field you have noticed to be incorrect:
1.
2.
3.
4.
5.
Press and hold down Button 1 until “set” appears on the display.
Using Buttons 1 & 2 to scroll, move up and down the fields until the value to be changed is on
screen.
Press Button 3. The “SEt” on the display will start to flash.
Using Buttons 1 & 2 to scroll, adjust the setting to the one shown on the table above.
Save the setting by pressing Button 3. The “SEtwill return to the steady state.
DO
DF
SX
CL
CX
CN
FN
MM
Field
6
4
70
200
190
6
3
2
Value