Installation manual

ENGLISH
Conergy AS
Owners Manual
21
6.3.3 Final connections:
1. Fit the 600mm Flexible Connector (P/No 60-
1124) to the top Fill Fitting on the Pump Module.
This connector is used for the Solar Flow line,
and is designed to be long enough to reach a
stub-out or similar connection on the wall.
2. Fit a 225mm Flexible Connector (P/No 60-1115)
to the other brass nipple on the HEM-25-B
module. This connector is used for the Solar
Return line, and is designed to be long enough
to reach a stub-out or similar connection on the
wall.
3. Plug the Hot Temperature Probe Assembly (P/No 35-1007) into the socket on the base of the Pump
Module. This plug will only fit one way. The temperature probe is inserted into the thermowell at
the hot connection of the collectors.
4. Ensure that the probe pocket is dry before inserting the probe and that it is sealed with silicone
or another suitable weather protection once the probe is in place.
6.3.2 Installing the pump module:
1. Ensure that the pump module is installed in an accessible position.
2. Fit the brass nipples (P/No 60-5066) to both the connection ports on the HEM-25-B module.
3. Take one Fill Fitting (P/No 60-5157), and using a suitable thread sealant, fasten to the outlet side
of the pump on the pump module. Remove the
check valve in this port on PM-600 modules.
4. Take the second Fill Fitting and fasten it to the
Gland Union (P/No 60-1032) using a suitable
thread sealant. Attach the Gland Union to the
Pump Module. A seal is obtained at this
junction by the rubber washer of the Gland
Union.
5. Loosely attach one end of the 225mm Flexible
Connector (P/No 60-1115) to the brass nipple
on the HEM-25-B module. Loosely attach the
other end to the bottom fill fitting on the pump
module.
5. With the exible connector loosely fitted, move the pump module into position on the storage vessel
and fix in place with the self-drilling screws supplied. Ensure the exible connector is not kinked in
any way, and the pump module is vertical. Tighten the loose nuts on the flexible connector.
60-5157
60-1032
60-5157
60-1115
60-5066
60-5066
6 Connections at the Storage Tank
60-1115
35-1007
60-1117