6 Installation Instructions
Envirosun TS Installation Manual Rev5b PVNW.docx Page 24
Electrical entry for the electric AES is achieved via a 20mm opening adjacent the element
surround.
Figure 6.17 Electrical entry
A cable gland with orange circular cable, or 19mm conduit with 3 core TPS cable must be
used to make electrical supply to the unit.
The power supply must be protected by an individual fuse or circuit breaker rated
to suit the booster size.
The supply to the solar water heater can be operated directly from the switchboard or via
a remotely mounted switch or time clock as requested by the customer.
A means for disconnection (e.g. isolator) must be included in the xed wiring to the solar
water heater in accordance with the wiring rules.
Final electrical connection at the solar water heater is as follows:
1. Earth - connected to the earthing stud marked with the earth symbol;
2. Active - connected to the terminal block position marked A or Active;
3. Neutral - connected to the terminal block position marked N or Neutral.
Do not turn on the power supply until the solar water heater has been filled with
water and pressurised.
There is a risk of damage to the system if the installation sequence is not followed.
20mm entry
Thermostat
Terminal block
5mm Earth stud
Electrical element