Installation manual

ENGLISH
Conergy TS
Installation Manual
4
For gas AES systems the electric element in the storage tank is not connected to an electricity
supply. Instead a continuous flow gas water heater is tted adjacent to the storage tank and in
series with the hot water supply from the storage tank and the household hot water pipe system.
As the hot water from the solar storage tank passes through the gas heater its temperature is
automatically monitored. If the temperature is below 60 °C the gas heater will add the heat required
to deliver hot water of at least 60 °C. If the water temperature is above 60 °C the gas heater is
programmed not to ignite.
1 Installation Information
1.4
Conergy TS model number explained
The model number of the system is divided into sections to describe the system which you have
installed. For example: TS300/4/0/E24/V/E20SB.
The rst two digits are used to determine the system type eg. TS300/4/O/E24/V/E20SB. TS is a
thermosiphon system.
The next three digits are used to determine the tank storage volume eg. TS300/4/O/E24/V/E20SB.
In the example 300 indicates that the storage volume is a nominal 300 litres. 180 would indicate a
nominal storage volume of 180 litres.
The fourth digit indicates the nominal collector surface area eg. TS300/4/O/E24/V/E20SB. In the
example 4 indicates 4m
2
and 6 would indicate 6m
2
.
The next gure indicates the tank model type eg. TS300/4/O/E24/V/E20SB. In the example O indicates
an open circuit tank and a C would indicate a closed circuit tank.
The next gures indicate the AES model type eg. TS300/4/O/E24/V/E20SB. In the example E24
indicates an electric 2.4kW AES a G21 would indicate a 21 litre/min gas AES.
The next figure indicates the tank construction eg. TS300/4/O/E24/V/E20SB. In the example V
indicates a vitreous enamelled tank and an S would indicate a stainless steel tank.
The nal 5 figures indicate the Collector model eg. TS300/4/O/E24/V/E20SB. In the example the
collectors are model E20SB. Other models are E20BC, E25BC or F20LC.