System information
1. CONFIGURATION OVER WEB BROWSER
1.11 Mobile WAN configuration
This item is not available for industrial router XR5i v2.
The form for configuration of a connection to the mobile network can be invoked by select-
ing the Mobile WAN item in the main menu of the router web interface.
1.11.1 Connection to mobile network
If the Create connection to mobile network item is selected, the router automatically tries
to establish connection after switching-on.
Item Description
Carrier Defines carrier and used transmission technology
APN Network identifier (Access Point Name)
Username User name to log into the GSM network
Password Password to log into the GSM network
Authentication Authentication protocol in GSM network:
• PAP or CHAP – Router is chosen one of the authentication methods.
• PAP – It is used PAP authentication method.
• CHAP – It is used CHAP authentication method.
IP Address IP address of SIM card. The user sets the IP address, only in the case
IP address was assigned of the operator.
Phone Number Telephone number to dial GPRS or CSD connection. Router as a de-
fault telephone number used *99***1 #.
Operator This item can be defined PLNM preferred carrier code
Network type • Automatic selection – Router automatically selects a specific trans-
mission method according to the availability of transmission technology.
• Furthermore, according to the type of router – it is also possible to
select a specific method of data transmission (GPRS, UMTS, . . . ).
PIN PIN parameter should be set only if it requires a SIM card router. SIM
card is blocked in case of several bad attempts to enter the PIN.
MRU Maximum Receiving Unit – It’s an identifier of maximum size of packet,
which is possible to receive in a given environment. Default value is
1500 B. Other settings may cause incorrect transmission of data.
MTU Maximum Transmission Unit – It’s an identifier of max. size of packet,
which is possible to transfer in a given environment. Default value is
1500 B. Other settings may cause incorrect transmission of data.
Table 16: Mobile WAN connection configuration
19
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de