Specifications

DESCRIPTION OF THE UR5 ROUTER
15
2.10.5. Connection of the Port1 Connector – CNT
Panel socket RJ45.
Pin
number
Signal mark Description Data flow direction
1 BIN1/CNT1
Binary input/counter input Input
2 BIN2/CNT2
Binary input/counter input Input
3 BIN3
Binary input Input
4 BIN4
Binary input Input
5 GND
Signal ground
6 OUT1
Binary output (open collector) Output
7 AN1
Analogy input Input
8 AN2
Analogy input Input
The user interface CNT is for monitoring and processing of analogy and binary
signals and to control (settings) of binary signal. To disposition are 2 counter and 2 binary
inputs or 4 binary inputs, 2 analogy inputs a 1 binary output. The settings of binaries
and counters inputs by the help of firmware in which it is defined the singles inputs
and output.
Typical connection of UR5 measuring circuits: