System information
CONFIGURATION
1.23. SMS configuration
SMS Configuration can be called up by option $$ item in the menu. SMS
configuration defines the options for sending SMS messages from the router at different
defined events and states of the router. In the first part of window it configuration send SMS.
"!+
Send SMS on power up Automatic sending of SMS messages after power up
Send SMS on PPP
connect
Automatic sending SMS message after PPP connection.
Send SMS on PPP
disconnect
Automatic sending SMS message after PPP disconnection.
Send SMS when
datalimit exceeded
Automatic sending SMS message after datalimit exceeded.
Send SMS when binary
input on I/O port (BIN0)
is active
Automatic sending SMS message after binary input on I/O port
(BIN0) is active. Text of message is intended parameter BIN0.
Send SMS when binary
input on expansion port
(BIN1-BIN4) is active
Automatic sending SMS message after binary input on expansion
port (BIN1-BIN4) is active. Text of message is intended parameter
BIN1 - BIN4.
Add timestamp to SMS
Adds time stamp to sent SMS messages. This stamp has a fixed
format YYYY-MM-DD hh:mm:ss.
Phone Number 1
Telephone numbers for sending automatically generated SMS.Phone Number 2
Phone Number 3
Unit ID The name of the router that will be sent in an SMS.
BIN0 - SMS SMS text messages when activate the binary input on the router.
BIN1 - SMS
SMS text messages when activate the binary input on theexpansion
port.
BIN2 - SMS SMS text messages when activate the binary input on the router.
BIN3 - SMS SMS text messages when activate the binary input on the router.
BIN4 - SMS SMS text messages when activate the binary input on the router.
Table 46: Send SMS configuration
In the second part of the window it is possible to set function 6!
$$. After this it is possible to establish and close PPP connection by SMS message.
"!+
Phone Number 1
This control can be configured for up to three numbers. If is set
Enable remote control via SMS, all incoming SMS are processed
and deleted. In the default settings this parameter is turned on.
Phone Number 2
Phone Number 3
Table 47: Control via SMS configuration
If no phone number is filled in, then it is possible to restart the router with the help
of SMS in the form of Reboot from any phone number. While filling of one, two or three
numbers it is possible to control the router with the help of an SMS sent only from these
numbers. While filling of sign “*” it is possible control the router with the help of an SMS sent
from every numbers.
48