System information

CONFIGURATION
In the case of a failed build a PPP connection is recommended to check the accuracy
of entered data. Alternatively, try a different authentication method or network type.
'('&(("$!)
The choice Get DNS address from operator is given for easier configuration
on client side. If this field is filled in, then the router tries to get an IP address of primary
and secondary DNS server from the operator automatically.
'('&(2(-!1 !!!)
If the Check PPP connection option is selected, it has active control of connection
over PPP. The modem will automatically send the ping question to the selected domain
name or IP address in periodic time intervals. If the PING failed, new ping be sent
immediately. After three unsuccessfully pings on appropriate IP address the router
terminates connection and tries to establish a new connection. It is possible to use,
for example, the DNS server of a mobile operator as the ping IP address.
 "!+
Ping IP Address Destinations IP address or domain name of ping queries.
Ping Interval Time intervals between the outgoing pings.
Table 15: Check PPP connection configuration
If the Enable Traffic Monitoring option is selected, then the router stops sending
ping questions to the Ping IP Address and it will watch traffic in PPP connection. If PPP
connection is without traffic longer than the Ping Interval, then the router sends ping
questions to the Ping IP Address.
Attention! We recommend checking the PPP connection in case of uninterrupted
running.
'('&(3("!)
 "!+
Data limit With this parameter you can set the maximum expected amount of data
transmitted (sent and received) over GPRS in one billing period (month).
Warning Threshold Parameter Warning Threshold determine per cent of Data Limit
in the range of 50% to 99%, which if is exceeded, then the router sends
SMS in the form Router has exceeded (value of Warning Threshold) o
data limit.
Accounting Start Parameter sets the day of the month in which the billing cycle starts SIM
card used. Start of the billing period defines the operator, which gives the
SIM card. The router begin to count the transferred data since that day
Table 16: Data limit configuration
If the parameter Switch to _____ when data limit is exceeded and switch to default
SIM card when data limit isn't exceeded (see next) or Send SMS when datalimit is exceeded
(see SMS configuration) are not selected the data limit will not count.