System information

1. CONFIGURATION OVER WEB BROWSER
Item Description
Baudrate Communication speed.
Parity Control parity bit:
none data will be sent without parity
even data will be sent with even parity
odd data will be sent with odd parity
Stop Bits Number of stop bit.
Table 52: SNMP configuration (MBUS extension)
Parameters Enable XC-CNT extension and Enable M-BUS extension can not be checked
together.
By choosing Enable reporting to supervisor y system and enter the IP Address and Period
it is possible to send statistical information to the monitoring system R-SeeNet.
Item Description
IP Address IP address
Period Period of sending statistical information (in minutes)
Table 53: SNMP configuration (R-SeeNet)
Every monitor value is uniquely identified by the help of number identifier OID Object
Identifier. For binary input and output the following range of OID is used:
OID Description
.1.3.6.1.4.1.30140.2.3.1.0 Binary input BIN0 (values 0,1)
.1.3.6.1.4.1.30140.2.3.2.0 Binary output OUT0 (values 0,1)
Table 54: Object identifier for binary input and output
For the expansion port CNT the following range of OID is used:
OID Description
.1.3.6.1.4.1.30140.2.1.1.0 Analogy input AN1 (range 0-4095)
.1.3.6.1.4.1.30140.2.1.2.0 Analogy input AN2 (range 0-4095)
.1.3.6.1.4.1.30140.2.1.3.0 Counter input CNT1 (range 0-4294967295)
.1.3.6.1.4.1.30140.2.1.4.0 Counter input CNT2 (range 0-4294967295)
.1.3.6.1.4.1.30140.2.1.5.0 Binary input BIN1 (values 0,1)
Continued on next page