System information
1. CONFIGURATION OVER WEB BROWSER
Continued from previous page
Item Description
Switch to SIM card on the other
module when sig. strength drops
below "weak" level (and is above
"fair" level on target config.) and
switch to default SIM card when
sig. strength is above "fair" level
This parameter enables switching to specified SIM
card or APN, when the signal strength drops below
specified value (and is above specified value on target
configuration). If the signal strength is above specified
value, this parameter enables switching back to de-
fault SIM card.
Switch to default SIM card after
timeout
This parameter defines the method, how the router will
try to switch back to default SIM card or default APN.
Table 23: Switch between SIM card configurations
Switching between SIM cards on the ground of signal strength is performed according to
the "weak" (lower limit) and "fair" (upper limit) values. It is possible to define the following
properties:
Item Description
Levels for GPRS/EDGE Limits for GRPS/EDGE technology
Levels for UMTS/HSPA+ Limits for UMTS/HSPA+ technology
Levels for CDMA Limits for CDMA technology
Sampling Interval The frequency of making samples
Filter Width Filter width for calculating the moving average from
loaded values of signal strength. The first value indi-
cates the fewest number of loaded samples for which
the value of calculated average is valid and can be
used to evaluate the relevant condition. The second
value is a filter width in the steady state when the mov-
ing average algorithm is applied (ie. if another sample
is loaded, replaces the oldest one, which means that
the filter width remains constant).
Table 24: Properties defining switching between SIM cards
The following parameters define the time after which the router attempts to go back to the
default SIM card or APN.
Item Description
Initial timeout The first attempt to switch back to the primary SIM card or APN
shall be made for the time defined in the parameter Initial Time-
out, range of this parameter is from 1 to 10000 minutes.
Continued on next page
27