EDGE router ER 75i, ER 75i DUO, ER 75i SL and ER 75i DUO SL USER’S GUIDE LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONTENTS Contents 1. 2. Safety instructions Description of the ER 75i, ER 75i DUO, ER 75i SL and ER 75i DUO SL routers 2.1. Introduction 2.2. Delivery Identification 2.3. Antenna Connection 2.4. SIM Card Reader 2.5. Power Supply 2.6. Technical parameters 2.7. Description of individual components of the router 2.7.1. GSM/GPRS/EDGE module 2.7.2. Control microcomputer 2.8. User interfaces (Connectors) 2.8.1. Connection of the PWR Supply Connector 2.8.2. Connection of the ETH Connector 2.8.3.
CONTENTS 4.20. SMS Configuration 4.21. Expansion Port Configuration 4.22. Start-up script 4.22.1. IO program 4.23. Up/Down script 4.24. Automatic update configuration 4.25. Change profile 4.26. Change password 4.27. Set real time clock 4.28. Set SMS service center address 4.29. Unlock SIM Card 4.30. Send SMS 4.31. Backup Configuration 4.32. Restore Configuration 4.33. Update firmware 4.34. Reboot 4.35. Default settings 4.35.1. LAN Configuration 4.35.2. VRRP Configuration 4.35.3. Firewall Configuration 4.35.
CONTENTS Symbols used Danger – important notice, which may have an influence on the user’s safety or the function of the device. Attention – notice of possible problems, which can arise in specific cases. Information, notice – information, which contains useful advice or special interest. GPL license Source codes under GPL license are available free of charge by sending email to info@conel.cz. Declared quality system ISO 9001 Conel s.r.o.
SAFETY INSTRUCTIONS 1. Safety instructions Please, observe the following instructions: • The communication module must be used in compliance with any and all applicable international and national laws and in compliance with any special restrictions regulating the utilization of the communication module in prescribed applications and environments.
DESCRIPTION 2. Description of the ER 75i, ER 75i DUO, ER 75i SL and ER 75i DUO SL routers 2.1. Introduction EDGE router is a compact electronic device based on the module which enables data transfers using GSM, GPRS and EDGE technologies. Primarily, the router expands the capabilities of the module by the option of connecting more PCs by means of the built-in Ethernet interface. In addition, the firmware of the router provides automatic establishment and maintenance of GPRS connection.
DESCRIPTION 2.2.
DESCRIPTION Basic delivered set of router includes: • EDGE router ER 75i or ER 75i DUO or ER 75i SL or ER 75i DUO SL, • power supply, • crossover UTP cable, • external magnetic antenna, • installation CD containing instructions and drives, • plastic clips for the DIN bar with fixing screws. In addition to the basic it is possible to deliver: • expansion port RS232, RS485/RS422, M-BUSD or CNT (separation columns are in distribution), • USB A-B cable.
DESCRIPTION 2.4. SIM Card Reader The SIM card reader for 3 V and 1.8 V SIM cards is located on the front panel of the modem. For putting the modem into operation it is necessary to insert an activated SIM card with unblocked PIN in the reader. 1. Make sure that the modem is not being powered. 2. Press the small yellow button next to the reader to eject the reader holder. 3. Insert the SIM card in the reader holder and slide it in the reader. 2.5.
DESCRIPTION 2.7. Description of individual components of the router 2.7.1. GSM/GPRS/EDGE module The MC75i OEM module is used for GSM network wireless communication. It is integrated into the printed circuit board. The slide-out SIM card reader is accessible from the front panel. The FME antenna connector is accessible from the back panel. The router is equipped with a USB 2.0 Full Speed interface which is brought to the USB-B connector marked USB.
DESCRIPTION 2.8.
DESCRIPTION Rear panel ER 75i SL and ER 75i DUO SL Front panel ER 75i SL Front panel ER 75i DUO SL 12 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
DESCRIPTION 2.8.1. Connection of the PWR Supply Connector • Panel socket RJ12. Pin Signal Description number mark 1 +UN Positive pole of DC supply voltage (+10 to +30 VDC) 2 NC Signal not connected 3 NC Signal not connected 4 +UN Positive pole of DC supply voltage (+10 to +30 VDC) 5 GND Negative pole of DC supply voltage 6 GND Negative pole of DC supply voltage Circuit example: Pin 1 – +UN Pin 2 – NC Pin 3 – NC Pin 4 – +UN Pin 5 – GND Pin 6 – GND + DC Router • Panel socket MRT9.
DESCRIPTION 2.8.2. Connection of the ETH Connector Panel socket RJ45. Pin Signal Description number mark 1 TXD+ Transmit Data – positive pole 2 TXDTransmit Data – negative pole 3 RXD+ Receive Data – positive pole 4 ----5 ----6 RXDReceive Data – negative pole 7 ----8 ----ATTENTION! Port ETH is not POE (Power Over Ethernet) compatible! Data flow direction Input/Output Input/Output Input/Output Input/Output The ETH router connection: Switch USB UTP cable ETH Router PORT1 PWR 2.8.3.
DESCRIPTION 2.8.4. Connection of the optional connector PORT1 Panel socket RJ45. 2.8.4.1. Expansion port RS232 (RS232 – DCE – Data Communication Equipment) Pin No.
DESCRIPTION The router connection to equipment with full-value RS232 interface: Cable KD-2 ETH Router PORT1 PWR 2.8.4.2. Pin No.
DESCRIPTION Circuit example of the equipment with a router with data length more than 10 m: At RS485 data cable more than 10m it is need to use overvoltage protection on the router side! 2.8.4.3. Pin No.
DESCRIPTION Circuit example of the equipment with router with data length less than 10 m: Circuit example of the equipment with a router with data length more than 10 m: At RS422 data cable more than 10m it is need to use overvoltage protection on the router side! 18 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
DESCRIPTION 2.8.4.4. Pin No. Signal name 1 2 3 4 5 6 7 8 SGND SGND TxRxTxRx+ TxRxTxRx+ +12V EXT +12V EXT Expansion port M-BUSD Data flow direction Description Signal and power supply ground Signal and power supply ground M-BUS B (-) M-BUS A (+) M-BUS B (-) M-BUS A (+) External power supply External power supply Input/Output Input/Output Input/Output Input/Output ATTENTION! External supply is for converter M-BUSD! If galvanic separation is required the converter must have external power supply.
DESCRIPTION 2.8.4.5. Expansion port CNT Pin Signal mark Description Data flow direction number 1 BIN1/CNT1 Binary input/counter input Input 2 BIN2/CNT2 Binary input/counter input Input 3 BIN3 Binary input Input 4 BIN4 Binary input Input 5 GND Signal ground 6 OUT1 Binary output (open collector) Output 7 AN1 Analogue input Input 8 AN2 Analogue input Input The user interface CNT is for monitoring and processing of analogue and binary signals and to control (settings) of binary signals.
DESCRIPTION 2.9. Technical specification of optional PORT1 • Expansion port RS232 Expansion port RS232 Power supply Environment Internal Operating temperature Storage temperature Emission Immunity Safety Max. operating bus current Max. bit rate Max. overvoltage Max. total cable length (300Bd, 200nF/km) Standards RS232 specifications (EN 1434) • .... -20 .. +55 C -20 ..
DESCRIPTION Jumper J3 Jumper J3 Jumper J2 The jumper circuitry for internal supply The jumper circuitry for external supply Jumper J6 Jumpery J4 a J5 The jumper circuitry for RS485 • Jumper J2 The jumper circuitry for RS422 Expansion port M-BUSD Name of product Expansion port M-BUSD Power supply External Supply power Operating temperature Storage temperature Emission Immunity Safety Max. devices (each 1,5 mA) Max.
DESCRIPTION • Expansion port CNT Name of product Expansion port CNT Power supply Internal Sleep Environment Standards Inputs/Outputs Operation Operating temperature Storage temperature Emission Immunity Safety Isolation 2x counter 2x analogue inputs 2x binary inputs 1x output (open collector) Voltage resistance Sleeping mode Others …. 100 µA (counter is functional) 2 mA -20 .. +55 C -20 .. +85 C EN 55022/B ETS 300 342 EN 60950 EN 60747 Max. 100 Hz, Ratio max. 1:10 0 ..
DESCRIPTION 2.10. Modem status indication On the front and back panel of the modem there are altogether four LED indicators, which inform on the modem status. Panel Color Description Description Blinking 1:9 ................... join GPRS connection Blinking 9:1 ................... establishing of GPRS connection Permanently on ……….. starting of the ER 75i Front Green PWR Front Red GSM Blinking ………..GSM/GPRS communication in progress Front Yellow SIM On ......................
DESCRIPTION 2.12. Mechanical external dimensions and mounting recommendations 25 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
DESCRIPTION For the majority of applications with a built-in modem in a switch board it is possible to recognize two sorts of environments: • non public and industry environment of low voltage with high interference, • public environment of low voltage without high interference. For both of these environments it is possible to mount modems to a switch board, the following is no need to have examination immunity or issues in connection with EMC according to EN 60439-1 ed.2:00 + A1:04.
DESCRIPTION • sufficient space must be left before individual connectors for handling of cables, • for correct function of the modem we recommend to use in switch - board earthbonding distribution frame for grounding of power supply of modem, data cables and antenna, • the circuit diagram of the router is on the following pictures. 27 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
EXPANSION PORT MOUNTING 3. Expansion port mounting 3.1. Expansion port mounting for ER 75i and ER 75i DUO router Attention! Expansion port includes when the router is switched off. After unscrewing two screws (position 8) on the box bottom part (position 4) and removing box top part (position 3), connect the expansion port PORT1 (position 2) to connector J3 (see below) of the router B-ER-75i motherboard (position 1) from the TOP side.
EXPANSION PORT MOUNTING Parts list and description Part Description Number 1 EDGE router motherboard 1 2 Expansion port PORT1 1 3 Box top part 1 4 Box bottom part 1 5 Rear head 1 6 Front head 1 7 Spacers for expansion port PORT1 mounting to motherboard 3 8 Screw for box completion 2 29 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
EXPANSION PORT MOUNTING 3.2. Expansion port mounting for ER 75i SL and ER 75i DUO SL router Attention! Expansion port includes when the router is switched off. After unscrewing four screws (position 10) on the rear panel (position 5) and removing it is possible to take out the B-ER-75i motherboard (position 1). The expansion port PORT1 (position 2) is connected to connector J3 (see below) of the router B-ER-75i motherboard (position 1) from TOP side.
EXPANSION PORT MOUNTING Parts list and description Part Description Number 1 EDGE router motherboard 1 2 Expansion port PORT1 1 3 Left box part 1 4 Right box part 1 5 Rear head 1 6 Front head 1 7 Bottom box part 1 8 Top box part 1 9 Spacers for expansion port PORT1 mounting to motherboard 3 10 Screw for box completion 8 31 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4. Configuration setting over web browser Attention! If the SIM card is not inserted in the router, then it is impossible to operate. The inserted SIM card must have activated GPRS. Insert the SIM card when the router is switched-off. Monitoring of the status, configuration and administration of the router can be performed by means of the web interface, which is available after insertion of IP address of the modem into the web browser. The default IP address of the modem is 192.168.1.1.
CONFIGURATION 4.1. Network Status To view the system information about the modem operation, select the System Information menu item. The bottom part of the window contains information about the system memory usage.
CONFIGURATION 4.2. DHCP Status Information about IP addresses, which was leased to the router by the DHCP server, is possible to find in menu in sum DHCP: • • • • • lease 192.168.1.2 (generally IP address) – assigned IP address starts – information about time of assignation of IP address ends – information about time of termination IP address validity hardware ethernet – hardware MAC (unique) address uid – unique ID In the extreme the DHCP status can display two records for one IP address.
CONFIGURATION 4.5. DynDNS status DynDNS up - dating entry result on server www.dyndns.org can be called up in option DynDNS item in the menu. 4.6. System Log In case of any problems with connection to GPRS it is possible to view the system log by pressing the System Log menu item. The System log observes only connection to GPRS and formation of IPsec tunnel. The upper part of the window displays possible errors at GPRS connection establishment.
CONFIGURATION Program syslogd can be started with two options that modifies its behaviour. Option "S" followed by decimal number set maximal number of lines in one log file. Option "-R" followed by hostname or IP address enable logging to remote syslog daemon. For starting syslogd with these options you could modify script "/etc/init.d/syslog" or add lines "killall syslogd" and "syslogd &" into Startup Script. 4.7. LAN Configuration To enter the network configuration, select the LAN menu item.
CONFIGURATION Example of the network interface with dynamic DHCP server: 192.168.1.2 GSM/GPRS ETH 192.168.1.1 192.168.1.3 192.168.1.4 37 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION Example of the network interface with dynamic and static DHCP server: 192.168.1.2 192.168.1.3 192.168.1.4 ETH GSM/GPRS 192.168.1.1 192.168.1.10 01:23:45:67:89:ab 192.168.1.11 01:54:68:18:ba:7e 38 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION Example of the network interface with default gateway and DNS server: 192.168.1.2 192.168.1.3 192.168.1.4 ETH GSM/GPRS 192.168.1.1 192.168.1.20 39 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.8. VRRP Configuration To enter the VRRP configuration select the VRRP menu item. VRRP protocol (Virtual Router Redundancy Protocol) is a technique, by which it is possible to forward routing from main router to backup router in the case of the main router failure. If the Enable VRRP is checked, then it is possible to set the following parameters. Parameter Virtual Server IP Address sets virtual server IP address. This address should be the same for both routers.
CONFIGURATION Example of the VRRP protocol: Main router Virtual server ID 5 Host priority 255 192.168.1.2 APN 1 ETH 192.168.1.1 10.0.1.3 APN 2 192.168.1.3 Backup router Virtual server ID 5 Host priority 100 4.9. GPRS Configuration To enter the GPRS connection configuration select the GPRS menu item. If the Create GPRS connection option is selected, the modem automatically tries to establish GPRS connection after switching-on.
CONFIGURATION Attention! If one SIM card is inserted into the router, which has two different APN’s, the router cannot have the second SIM socket mounted. Otherwise it will switch to secondary APN false. Also, correct PIN must be filled. For SIM cards with two APN’s there will be the same PIN for both APN`s. Otherwise the SIM card can be blocked by false SIM PIN. The choice Get DNS address from operator is given for easier configuration on client side.
CONFIGURATION Parameter Switch to backup SIM card when binary input is active enables switching to secondary SIM card or secondary APN of the SIM card, when binary input ‘bin0’ is active. Parameter Switch to primary SIM card after timeout enable defines the method, how the router will try to switch back to default SIM card or default APN. The following parameters define the time after which the router attempts to go back to the default SIM card or APN.
CONFIGURATION The changes in settings will apply after pressing the Apply button. 44 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.10. Firewall Configuration By the help of a firewall it is possible to set IP addresses from which are possible to remotely access the router. The choice Allow remote access only from specified hosts is given for easier configuration of hosts. In this firewall configuration it is possible to set up to four remote accesses by the help of Source, Source IP Address, Protocol and Target Port.
CONFIGURATION Example of the firewall configuration: TCP/1000 10.0.2.123 171.92.5.45 ALL ICMP 142.2.26.54 46 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.11. NAT Configuration To enter the Network Address Translation configuration, select the NAT menu item. By checking off the Send all incoming packets to default server item and setting the Default Server item it is possible to put the router into the mode in which all incoming data from GPRS will be routed to the computer with the defined IP address. If the Enable remote HTTP access field and port number is filled in, then configuration of the router over web interface is possible.
CONFIGURATION Example of the configuration with one connection equipment on the router: 162.209.13.222 ppp0 10.0.0.1 192.168.1.2 In these configurations it is important to have marked choice of Send all remaining incoming packets it default server, IP address in this case is the address of the device behind the router. Connected equipment behind the router must have set Default Gateway on the router. Connected device replies, while PING on IP address of SIM card. 48 LUCOM GmbH * Ansbacher Str.
CONFIGURATION Example of the configuration with more connected equipment: SWITCH 162.209.13.222 10.0.0.1:81 ppp0 10.0.0.1 10.0.0.1:82 192.168.1.2:80 10.0.0.1:83 192.168.1.3:80 192.168.1.4:80 49 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION In this configuration equipment wired behind the router defines the address Server IP Address. The router replies, while PING on address of SIM card. Access on web interface of the equipment behind the router is possible by the help of Port Forwarding, when behind IP address of SIM is indicating public port of equipment on which we want to come up.
CONFIGURATION Authenticate Mode it is possible to choose authentication. On choice are none authentication, or by Pre-shared secret which set shared key for both off-side tunnel; or by Username/Password which enable authentication by CA Certificate, Username and Password; next can be X.509 Certificate (client), this enables authentication by CA Certificate, Local Certificate and Local Private Key; last possibility is X.
CONFIGURATION Example of the OpenVPN tunnel configuration: 192.168.1.2 192.168.2.2 A ppp0 10.0.0.1 192.168.1.0 tun0 19.16.1.0 ppp0 10.0.0.2 192.168.2.0 tun 0 19.16.2.0 B 192.168.1.3 OpenVPN tunnel 192.168.2.3 192.168.1.4 192.168.2.4 Default Gateway 192.168.2.1 Default Gateway 192.168.1.1 OpenVPN tunnel configuration: Protocol UDP Port Remote IP Address: Remote Subnet: Remote Subnet Mask: Local Interface IP Address: Remote Interface IP Address: Compression Authenticate mode: A UDP 1194 10.0.0.
CONFIGURATION 4.13. Ipsec Tunnel Configuration Ipsec tunnel configuration can be called up by option Ipsec item in the menu. Ipsec tunnel allows protected connection of two networks LAN to the one which looks like one homogenous. In the Ipsec Tunnels Configuration window are four rows, each row for one configured IPSec tunnel. The column Create switches on tunnels, other columns contain values view set in the Ipsec Tunnel Configuration windows; configuration is possible by the Edit button.
CONFIGURATION 54 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION Example of the IPSec Tunnel configuration: 192.168.1.2 192.168.2.2 ppp0 10.0.0.2 192.168.2.0 A B ppp0 10.0.0.1 192.168.1.0 192.168.1.3 IPSec tunnel 192.168.2.3 192.168.1.4 192.168.2.4 Default Gateway 192.168.1.1 Default Gateway 192.168.2.1 Ipsec tunnel configuration: Remote IP Address: Remote Subnet: Remote Subnet Mask: Local Subnet: Local Subnet Mask: Authenticate mode: Pre-shared key A 10.0.0.2 192.168.2.0 255.255.255.0 192.168.1.0 255.255.255.0 pre-shared key test B 10.0.0.
CONFIGURATION The tunnels are active after entry of choice Create x GRE tunnel.
CONFIGURATION 4.15. L2TP tunnel Configuration To enter the L2TP tunnels configuration, select the L2TP menu item. L2TP tunnel allows protected connection by password of two networks LAN to the one which it looks like one homogenous. The tunnels are active after enter of choice Create L2TP tunnel.
CONFIGURATION Example of the L2TP Tunnel configuration: 192.168.1.2 192.168.2.2 ppp0 10.0.0.2 192.168.2.1 A B ppp0 10.0.0.1 192.168.1.1 192.168.1.3 L2TP tunnel 192.168.2.3 192.168.1.4 192.168.2.4 Default Gateway 192.168.1.1 Default Gateway 192.168.2.1 L2TP tunnel Configuration: Mode Server IP Address Client Start IP Address: Client End IP Address: Local IP Address: Remote IP Address Remote Subnet Remote Subnet Mask Username Password A L2TP Server --192.168.1.2 192.168.1.254 192.168.1.1 --192.
CONFIGURATION 4.16. DynDNS Client Configuration DynDNS client Configuration can be called up by option DynDNS item in the menu. In the window can be defined a third order domain registered on server www.dyndns.org (Hostname), user name (Username) and password (Password). If you want to use a different server than www.dyndns.org, fill in his address to the item server (Server). If this item is left blank, the default server is used. The changes in settings will apply after pressing the Apply button.
CONFIGURATION 4.17. NTP Client Configuration NTP client Configuration can be called up by option NTP item in the menu. In the window can be defined the address prime (Primary NTP server Address) and secondary NTP server (Secondary NTP server Address), by the help of which the router, after first interface to the GPRS from make power supply, will adjust the inner clock. Example of NTP server address can be seenon ntp.isc.org/bin/view/Servers/StratumOneTimeServers.
CONFIGURATION and Stop Bits it is possible to monitor the meter status connected to the expansion port M-BUSD status. Every monitor value is uniquely identified by the help of number identifier OID – Object Identifier. OID is finished by „.9“. For the expansion port CNT the following range of OID is used: OID Description .1.3.6.1.4.1.30140.2.1.1.0 .1.3.6.1.4.1.30140.2.1.2.0 .1.3.6.1.4.1.30140.2.1.3.0 .1.3.6.1.4.1.30140.2.1.4.0 .1.3.6.1.4.1.30140.2.1.5.0 .1.3.6.1.4.1.30140.2.1.6.0 .1.3.6.1.4.1.30140.2.1.
CONFIGURATION Example of the MIB browser: It is important to set the IP address of the SNMP agent (ER 75i) in field Remote SNMP agent. After enter the IP address is in a MIB tree part is possible show object identifier. The path to objects is: iso->org->dod->internet->private->enterprises->conel->protocols 4.19. SMTP Configuration Configuration of SMTP can be entered by clicking on SMTP menu item. In the window, there is possible to enter login values to e-mail server, from which e-mails will be sent.
CONFIGURATION 4.20. SMS Configuration In the SMS Configuration menu it is possible to select automatic sending of SMS messages following power up (Send SMS on power up) and at the start (Send SMS on PPP connect) or the loss (Send SMS on PPP disconnect) of the PPP connection and at data limit exceeded (Send SMS when datalimit exceeded).
CONFIGURATION After powering up the router, at introduction of the telephone number comes SMS in the form of: ER75i (Unit ID) has been powered up. PLMN:xxxxx,Cell:xxxx,Channel:xx,Level:-xxdBm. Where PLMN is – number of mobile operator, Cell – number of cell, Channel – used channel, Level – level signal After PPP connect, at introduction of the telephone number comes SMS in the form: ER75i (Unit ID) has established PPP connection. IP address xxx.xxx.xxx.
CONFIGURATION Configuration of sending this SMS is following: 65 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION Example of the router configuration for SMS sending via serial interface: 66 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION Example of the router configuration for controlling via SMS from every phone numbers: 67 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION Example of the router configuration for controlling via SMS from two phone numbers: The SMS is possible to do for example in HyperTerminal program. After establishing connection with the router via serial interface or Ethernet, it is possible to do with SMS by the help of the next AT commands (more about AT commands see reference [1]): AT commands AT+CMGF=1 AT+CMGS=”tel.
CONFIGURATION For the text mode for SMS writing is used command AT+CMGF=1. AT+CMGF=1 Enter OK The SMS message is created by the help of command AT+CMGS=. After Enter button is pressed is displayed mark >, behind this mark it is possible to write your own SMS message. The SMS message is sent by the help of CTRL+Z (SMS sending takes a few minutes). SMS writing is possible to cancel by pressing Esc.
CONFIGURATION 4.21. Expansion Port Configuration The expansion port configuration can be called up by airbrush option External Port in menu. Inside the window can be defined Baudrate, number of Data bits, Parity, number of Stop bits, Protocol and Mode. Split timeout is for messages. In mode TCP server it is necessary to enter the TCP port, on which the router will listen to incoming requests about TCP connection. In mode TCP client it is necessary to enter the Server address and final TCP port.
CONFIGURATION Example of external port configuration: PC PLC ppp0 10.0.0.2 ETH ppp0 10.0.0.1 192.168.1.1 RS232 192.168.1.100 PC application settings: TCP connection on 10.0.0.2:2000 Default Gateway 192.168.1.1 ER-75i settings Mode: TCP server Server Address: TCP Port: 2000 PLC PC ppp0 10.0.0.2 RS232 RS232 ppp0 10.0.0.1 ER-75i settings Mode: TCP client Server Address: 10.0.0.2 TCP Port: 2000 ER-75i settings Mode: TCP server Server Address: TCP Port: 2000 71 LUCOM GmbH * Ansbacher Str.
CONFIGURATION 4.22. Start-up script In the window Startup Script it is possible to create own scripts which will be executed after all initial scripts. This script is not stored or restored when using web interface backup or restore option. The changes in settings will apply after pressing the Apply button. 4.22.1. IO program Program "io" can be used to set binary outputs (syntax: io set out0|out1 0|1) and get state of binary inputs (syntax: io get bin0|bin1|bin2|bin3|bin4).
CONFIGURATION io get bin3 BIN3=$? if [ "$BIN3" != "$OLD3" ]; then if [ "$BIN3" = "1" ]; then gsmsms 739546801 "test SMS bin3-1" fi if [ "$BIN3" = "0" ]; then gsmsms 739546801 "test SMS bin3-0" fi OLD3=$BIN3 fi sleep 2 done Change take effect after restarting router by the help of button Reboot in web administration or by SMS message. 73 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.23. Up/Down script In the window Up/Down Script it is possible to create own scripts. In the item Up script is defined scripts, which begins after establishing a PPP connection. In the item Down Script is defines script, which begins after lost a PPP connection. This script is not stored or restored when using web interface backup or restores option. The changes in settings will apply after pressing the Apply button.
CONFIGURATION concrete configuration name which will be download to the router. When using parameter Unit ID, hardware MAC address in configuration name will not be used. Automatic configuration update starts 5 minutes after turning on the router and then every 24 hours or it is possible to set the time of automatic configuration in parameter Update Hour. If the entered URL is different configuration than in the router then the router downloads this configuration and restarts itself.
CONFIGURATION 4.27. Set real time clock One – shot inner clock of the router etting can be called up in option Set Real Time Clock item in the menu. Clocks are set according to the engaged NTP server after pushbutton operation Appl. 4.28. Set SMS service center address In some cases it is need to set phone number of the SMS service centre because of SMS sending. This parameter cannot be set when the SIM card has set phone number of the SMS service centre.
CONFIGURATION 4.30. Send SMS Sending SMS messages is possible in menu Send SMS. The SMS message will be sent after entering the Phone number and text SMS (Message) and by pushing button Send. SMS message sending via HTTP request is in the form: GET /send_exec.cgi?phone=%2B420712345678&message=Test HTTP/1.1 Authorization: Basic cm9vdDpyb290 HTTP request will be sent to TCP connection on router port 80 which sends an SMS message Test to phone number 420712345678.
CONFIGURATION 4.33. Update firmware To view the information about the firmware version and instructions for its update select the Update Firmware menu item. The new firmware will be checked after pressing Browse button and update the following pressing the Update button. After successful firmware updating the following statement is listed: There is information about updating of the FLASH memory. By firmware actualization from 1.1.1 version the router configuration is remains include IP address.
CONFIGURATION 4.35. Default settings After green LED starts to blink it is possible to restore initial settings of the router by pressing button RST on front panel. After press button RST it is restoration of the configuration and reset (green LED will be on). 4.35.1. LAN Configuration 79 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.35.2. VRRP Configuration 4.35.3. Firewall Configuration 80 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.35.4. GPRS Configuration 81 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.35.5. NAT Configuration 4.35.6. OpenVPN Tunnel Configuration 82 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 83 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.35.7. Ipsec Tunnel Configuration 84 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.35.8. GRE Tunnel Configuration 4.35.9. L2TP Configuration 85 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.35.10. DynDNS Configuration 4.35.11. NTP Configuration 4.35.12. SNMP Configuration 86 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.35.13. SMTP Configuration 4.35.14. SMS Configuration 87 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.35.15. Expansion Port Configuration 4.35.16. Startup Script 88 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 4.35.17. Up/Down Script 4.35.18. Automatic Update 89 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
CONFIGURATION 5. Configuration setting over Telnet Attention! If the SIM card isn’t included in the router, it is impossible for the router to operate. The Included SIM card must be activated for GPRS transmissions. Insert the SIM card when the router is switched off. Monitoring of status, configuration and administration of the router can be performed by means of the Telnet interface. After IP address entry to the Telnet interface it is possible to configure the router by the help of commands.
DRIVERS 6. Driver installation Connect the USB cable to the router and to the PC. Windows detects router as a new USB modem, starts the Add Hardware wizard and requests the driver for "MC75i" or „Siemens AG WM USB Modem“. Follow the instructions of the wizard and enter the path to the "usbmodem.inf" file. Windows will copy the needed files to your computer and configure the modem by assigning a free COM port. After completion of copying the files click on the Finish button.
DRIVERS You will find the installed modem in the Phone and modem options control panel (Start | Settings | Control Panel | Phone and Modem Options | Modems). . You can change the assigned COM port in the Device Manager. Select “Siemens AG WM USB Modem” in the installed devices list, click on Properties, select the Details tab and click on the Advanced port settings button. Then select the required free COM port from the COM port number menu.
AT COMMANDS, PROBLEMS, REFERENCE AND FAQ 7. Control by AT commands The router is controlled and programmed by AT commands. Structure of the AT command match used module MC75i. AT commands are possible to find on website www.siemens.com/wm. 8. Possible problems Some network cards are able to be set in situation, when it is not possible to connect the router.
AT COMMANDS, PROBLEMS, REFERENCE AND FAQ DynDNS not function. In private APN not functional. If the same IP address is recorded in your canonic name as dynamically assign address, it means that the operator is using NAT or firewall. NAT is possible to verify by the help of the ping on address of your server with static IP address and by the help of the router address verify and address in ping. Firewall is possible to verify, for example by remote access on web interface.
AT COMMANDS, PROBLEMS, REFERENCE AND FAQ 11. Customer’s care Up to date information about the product are on website: http://www.conel.cz/ Upkeep-advices: The SIM-card must be handled carefully as with a credit card. Do not bend, do not scratch on this and do not expose to static electricity.
DISPOSAL INFORMATIONS 12. Product disposal information The WEEE (Waste Electrical and Electronic Equipment: 2002/96/EC) directive has been introduced to ensure that electrical/electronic products are recycled using the best available recovery techniques to minimize the impact on the environment. This product contains high quality materials and components which can be recycled. At the end of it’s life this product MUST NOT be mixed with other commercial waste for disposal.
GUARANTEE CLAIM GUIDELINES 13. Guarantee Claim Guidelines Dear customer, The product that you have purchased was tested by the manufacturer and, before it was sold, the product’s functions were checked once more by our company’s technician. However if, in spite of the above-mentioned measures, a breakdown of this product occurs during the guarantee period, which makes proper utilization of the product impossible, we ask you to observe the Guarantee Claim Guidelines when asserting a guarantee claim.
GUARANTEE CLAIM GUIDELINES hereupon onto the seller, and the ownership of the new product, onto the buyer. A new guarantee period starts running from the date of acceptance of the new product. In the event that the seller, upon agreement with the customer, has settled the guarantee claim by exchanging the object of the guarantee claim for a faultless product, the new guarantee of the product shall expire as follows: 1.
GUARANTEE CLAIM GUIDELINES Other guarantee claim conditions The fact that the object of the guarantee claim does not correspond to parameters that have been set for other similar types of products can not be considered to be a defect. For the assessment whether a defect has occurred, the product parameters included in the technical documentation of the product are decisive.
GUARANTEE CERTIFICATE 14. Guarantee certificate Type of the device Serial number Guarantee period (in months) Seller Date of sale Stamp of the seller 100 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
GUARANTEE CERTIFICATE 1 2 3 4 5 YES - NO YES - NO YES - NO YES - NO YES - NO Date of reception of the guarantee claim by the seller Number of the guarantee claim report Date of reception of the device into the repair shop Date of completion of the repair by the repair shop Number of the receipt form of the repair shop Guarantee repair New serial number of the device (IMEI) Comments Stamp of the repair shop 101 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax.