Specifications
CDA70 MODEM DESCRIPTION
33
Parameter name
Set value
range
Parameter description
Low threshold RF
signal level
-90 up to -130
dBm
Threshold of RF signal level when the RF
channel is considered to be busy.
Maximum number of
linked packets
1 up to 10 Maximum number of packets which are
linked together and send at once. This value
must be optimized regarding channel loading
and accessibility.
Additive constant for
RSSI
--- Additive constant for RSSI size information.
Multi constant for
RSSI
--- Multiplicative constant for RSSI size
information.
Radio module check
YES/NO By setting this parameter to YES the radio
module setting is checked against modem
configuration at start-up and one hour later.
Clock synchronization
network address
0000 up to
9999 Hex
Network address which can be used for
modem time synchronization.
Clock synchronization
interface address
0 up to 255 Interface address which can be used for
modem time synchronization.
Log resets
YES/NO When this parameter is set to YES, than
reset information are stored to the journal.
Log RF channel
YES/NO When this parameter is set to YES, than
radio channel information are stored
to the journal.
Log COM ports
YES/NO When this parameter is set to YES, than
COM information are stored to the journal.
Log PPP protocol
YES/NO When this parameter is set to YES, than PPP
information are stored to the journal. For
CDA-70 modem this parameter is
unimportant.
Log DNS service
YES/NO If Agnep protocol is set on the Ethernet port
and this parameter is set to YES than DNS
information is stored to the journal.