User Manual

16
I. SUMMARY TABLE FOR ORDINARY MAINTENANCE
This table lists the recommended service intervals for the systems noted.
Part Object
Interval
Daily 50 h 250 h 500 h 1500 h
Diesel engine Engine oil CL ST
Oil filter ST
Cooling liquid CL ST
Air filter VF ST
Fuel CL
Hydraulic circuit
Fuel filter ST
Hydraulic oil CL ST1 ST(*)
Filter VF ST1 ST(*)
Bull-wheel gear box Oil CL ST1 ST(*)
Bull-wheel negative
brake
Oil CL ST1 ST(*)
Reel winder negative
brake
Oil CL ST1 ST(*)
Bull-wheels greasing
circuit
Reel winder
Gears GR
Chain transmission GR
Level winder screw GR
Pawl VF
Legend:
CL Check the level (and possible filling up)
GR Grease
ST Replace
ST1 Replace (only for the first time)
VF Check
(*) Or in any case every year
J. EXTENDED STORAGE
When an extended storage period is anticipated (two months or more) coat
external parts with waterproof protectant.
During the storage period, start the machine at least once every two months and
let the engine idle for approx. one hour. Do this so that oil enters the hydraulic
system and coats all gaskets, o-rings, etc.
The machine should be stored under a roof. Do not tarp the machine as excess
moisture may collect under it and cause damage to the system.
If the machine is stored for a year or more, replace the hydraulic circuit’s oil and
filters prior to startup.