Manual

8
Set Up the Blower
This manual contains setup and operating instructions for the Gulfstream 200 micro
fiber blower.
A. DETERMINE FIBER SIZE
Determine size of fiber to be installed. To provide optimal traction and grip, if fiber
diameter is 1.5mm or less, the top belt of blower must be changed to a flat belt which
is included in the common parts kit. This flat belt is to be used in combination with the
bottom grooved belt, so that adequate contact and proper push force can be applied
to the fiber. Refer to Section 9 for belt replacement instructions.
B. SELECT CABLE SEAL & DUCT PACK
Choose the correct cable seal and duct pack for the particular application according to
duct and cable size. Refer to Cable Seal and Duct Pack selection charts.
5.
CABLE SEAL SELECTION
CABLE OD (mm) CABLE SEAL KIT PN DUCT PACK PN
0.8-1.5 08783074 08783051; 08783052; 08783053
1.5-2.0 08783057 08783051; 08783052; 08783053
2.0-2.5 08783058 08783051; 08783052; 08783053
2.5-3.0 08783064 08783051; 08783052; 08783053
3.0-3.5 08783059 08783051; 08783052; 08783053
3.5-4.0 08783060 08783052; 08783053
4.0-4.5 08783061 08783052; 08783053
4.5-5.0 08783062 08783052; 08783053
5.0-5.5 08783063 08783052; 08783053
DUCT PACK SELECTION
DUCT OD (mm) DUCT PACK PN
5.0mm 08783051
7.0mm 08783051
8.0mm 08783052
8.5mm 08783052
10.0mm 08783052
12.0mm 08783053
12.7mm 08783053