Owner's manual

WARNING: Escaping fluids under pressure can penetrate the skin and
cause serious personal injury. Observe the following precautions to
avoid hydraulic hazards:
•Tightenallconnectionsbeforeapplyingpressure.Relievepressure
before connecting or disconnecting hoses.
•Checkforleakswithapieceofcardboard.Donotusehands!
•Donotexceedworkingpressureofhydraulichoses.Visuallyinspect
hoses regularly and replace if damaged.
3. Run the blower for approximately 1 minute to remove any trapped air and then
stop the blower and hydraulic power source.
C. SET UP THE ELECTRONIC CONTROL BOX
1. Install Electronic Control Box on blower and secure with 1/4 turn fasteners
(Figure 61).
2. Attach Power Cord and plug into 12 volt power supply (Figure 62). Take
caution in routing the electrical cord to prevent a tripping hazard.
3. Attach solenoid valve, front tractor sensor,
rear counter sensor, and transducer plugs
(Figure 63).
4. Turn on control box power (Figure 64).
Select the Traction Control required.
Press the Traction Control button ON to
activate. This stops the blower's tractor
drive if the slippage or speed parameters
are exceeded. Press OFF to disable this
function.
29
Figure 62. Attach Power Cord
Figure 61. Install Electronic
Control Box
Figure 63. Attach Sensor Plugs