Owner's manual
6. Press Touch Screen “LIMIT: XXXX” to open the Limit keypad.
7. Enter the desired pressure – suggested starting point is 800 PSI.
8. Place Cable in Blower from Rear Rollers through Tractor Drive. Push cable
through the duct until it stops against the Pulling Eye (Figure 13).
9. Place a mark on the Cable about 2" (51 mm) behind the Rear Rollers
(Figure 14).
10. Install top Venturi (Figure 15). Close Air Block and tighten (Figure 16).
11. From the Rear Rollers, pull out approximately 8' (2.4 m) of cable from
the blower.
12. To avoid start up pressure spikes, which will register on the pressure
transducer and produce a false pressure error, set the Hydraulic Flow Control
to the lowest speed by rotating the flow control knob clockwise until it stops.
14
Figure 13. Install Cable
Figure 14. Mark the Cable
Figure 15. Install Top Venturi
Figure 16. Close Air Block
and tighten