Manual

20
H. ELECTRONICS NOTE
When cleaning the machine, avoid direct spraying of water or steam on electronic
components or the control panel.
For the other periodic operations refer to the summary table for the ordinary
maintenance.
I. SUMMARY TABLE FOR ORDINARY MAINTENANCE
This table lists the recommended service intervals for the systems noted.
Part Object
Interval
Daily 50 h 250 h 500 h 1500 h
Diesel engine
Engine oil CL RP
Oil filter RP
Cooling liquid CL RP
Air filter CK RP
Fuel CL
Fuel filter RP
Hydraulic circuit
Hydraulic oil CL RP1 RP(*)
Filter CK RP1 RP(*)
Bull-wheel gear box Oil CL RP1 RP(*)
Reel winder
Gears GR
Chain transmission GR
Level winder screw GR
Pawl GR CK
Legend:
CL Check the level (and possible filling up)
GR Grease
RP Replace
RP1 Replace (only for the first time)
CK Check
(*) Or in any case every year
J. EXTENDED STORAGE
When an extended storage period is anticipated (two months or more) coat
external parts with waterproof protectant.
During the storage period, start the machine at least once every two months and
let the engine idle for approx. one hour. Do this so that oil enters the hydraulic
system and coats all gaskets, o-rings, etc.
The machine should be stored under a roof. Do not tarp the machine as excess
moisture may collect under it and cause damage to the system.
If the machine is stored for a year or more, replace the hydraulic circuit’s oil and
filters prior to startup.