Product Manual
Cautions:
1.Always wear protection gear like safety goggles, gloves, apron, and ear plugs while operating the pump
2.Never let any body part come in front of, or in contact with the control valve outlet
3.Always cut off air supply after use, so that media can't leak incase any of the pump component fails
4.Before attempting any maintenance or repair of this product, disconnect air supply and then squeeze control valve trigger to release fluid
pressure
5.Before switching the air supply on, check hoses for sign of wear, leak or loose fittings. Replace as necessary
6.In case of accident, immediately seek medical attention. Do no try to treat the injury yourself
7.Use only genuine factory parts for repair
8.Do not smoke when using / near the pump
9.Do not use the pump near a source of spark / open flames
10.In case of change of working fluid, at least 1 liter (or as desired) of new fluid should be discarded to avoid mixing of fluids
11.Operate pump for not more than 4 hours continuously
12.Use only natural compressed air for operating the pump
S1230, Rev C
No
smoking
Safety gloves
must be worn
Wear your
safety glasses
Safety overalls
must be worn
TROUBLESHOOTING
Air motor operates, but does
not dispense any grease
PROBLEM CAUSES REMEDYSr. Nr
1.
1.Grease is too thick / too cold
2.Grease drum is damaged causing the
follower plate to get stuck
3.Air pockets in grease
4.Inlet Pressure is too Less
1. Use NLGI No.2/ thinner grease. Store
grease in a warm place
2. Replace drum. Follower plate must be
able to travel all the way down freely
3. Shake the grease drum & manually
force down the follower plate to remove
air pockets
4. Inlet Air Pressure must at least be 60 PSI
(4 BAR).Increase inlet pressure
Air Motor cycles intermittently
with the trigger not pressed
2
Leakage in the assembly Check all the connections to ensure they
are air tight. Use thread sealant.