Instruction Manual
18 UPS3000/UPS3110/UPS3210 Operation & Maintenance Manual
2.11.4 SERIAL OUTPUT CONFIGURATION TABLE
EEPROM LOCATION 64
6 4 _ _ M L
0 = OPEN, 1 = CLOSED
MSD = MOST SIGNIFICANT DIGIT, LSD = LEAST SIGNIFICANT DIGIT
All serial characters are ASCII and consist of the following:
LSD
M
S1 Settings
Serial Output Data Format1 2 3 4
0 0 0 0 0 Format #1 Demand
1 1 0 0 0 Format #2 Demand
2 0 1 0 0 Format #1 Continuous
3 1 1 0 0 Format #2 Continuous
Table 2-8. M Serial Output Configuration
LSD
L
S1 Setting
Serial Output
Baud Rate
5 6 7 8
0 0 0 0 0 300
1 1 0 0 0 600
2 0 1 0 0 1200
3 1 1 0 0 2400
4 0 0 1 0 4800
5 1 0 1 0 9600
Table 2-9. L Serial Output Configuration
1 Start Bit
7 Data Bits
Odd Parity
2 Stop Bits
Table 2-10. Serial Character Settings