Specifications
There are 13 byte wide status and control registers. They are accessed at the following I/O
addresses:
l
210h for Status & Control Register 0;
l
211h for Status & Control Register 2;
l
212h for Status & Control Register 1;
l
213h for VME Address Capture Data & Control Registers; (refer to note)
l
214h for Watchdog Status & Control Register;
l
215h for Control and Status Register 4;
l
216h for Memory Page and Status Register;
l
217h for Status & Control Register 3;
l
218h for Long Duration Timer LS byte;
l
219h for Long Duration Timer Mid Low byte;
l
21Ah for Long Duration Timer Mid High byte;
l
21Bh for Long Duration Timer MS byte;
l
21Ch for Long Duration Timer Status & Control Register;
NOTE The functions provided by the VME Address Capture Data & Control registers are
described in Chapter 5. The functions of the remaining registers in this block are
detailed in the following sections.
8-2 VP 110/01x
Additional Local I/O Functions